A new fixation material for open-wedge tibial osteotomy for genu varum

被引:15
作者
Ribeiro, Cristiano Hossri [1 ]
Severino, Nilson Roberto [1 ]
Leite Cury, Ricardo de Paula [1 ]
de Oliveira, Victor Marques [1 ]
Avakian, Roger [1 ]
Ayhara, Tatsuo [1 ]
Arbix de Camargo, Osmar Pedro [1 ]
机构
[1] Irmandade Santa Casa Misericordia Sao Paulo FCMSC, Knee Surg Div, Dept Orthopaed & Traumatol, Fac Ciencias Med, Sao Paulo, Brazil
关键词
osteotomy; Knee; Osteoarthritis; Bone plates; Acquired joint deformities; TERM-FOLLOW-UP; KNEE; OSTEOARTHRITIS; GONARTHROSIS; SLOPE;
D O I
10.1016/j.knee.2009.01.007
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Varus deformity of the knee is a determining factor in the development of osteoarthrosis of the medial compartment. Open wedge osteotomy corrects the deformity and has quickly become popular due to the fact that the surgical technique can be easily reproduced, it spares loss of bone tissue in the metaphysiary region, and it does not require muscle dissection, reducing the risk of lesion of the fibular nerve. The objective of this study was to evaluate the characteristics of a new fixation implant (Anthony-K plate - France Bloc S.A, CE n0499, ISO 9001, EN 46001), in terms of its clinical improvement, correction of the deformity, and slope alteration. Twenty adult patients with varus deformity were evaluated, and submitted to open wedge high tibial osteotomy using the Anthony plate, between October 2004 and November 2006. The varus deformity was corrected in all cases, and there was a significant increase in the Lysholm score. Correlation analysis has shown that the greater the preoperative varus deformity, the larger the opening wedge used. Also, the greater the initial posterior tibial slope, the larger the final posterior tibial slope (p = 0.0168). There were no complications. The Anthony plate can be considered an alternative in the treatment of medial osteoarthrosis of the varus knee, enabling the correction of the deformity and improvement of the clinical picture. It occurs an increase in posterior tibial slope, similar to that observed with other fixation materials. More studies with the Anthony plate are necessary, after these encouraging results. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:366 / 370
页数:5
相关论文
共 26 条
[1]
Ahlback S, 1968, Acta Radiol Diagn, V277, P7
[3]
High tibial osteotomy with a calibrated osteotomy guide, rigid internal fixation, and early motion - Long-term follow-up [J].
Billings, A ;
Scott, DF ;
Camargo, MP ;
Hofmann, AA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (01) :70-79
[4]
Bombaci Hasan, 2005, Acta Orthop Traumatol Turc, V39, P404
[5]
CLARKE HD, SURG KNEE, V1, P13
[6]
OSTEOTOMY ABOUT KNEE FOR DEGENERATIVE AND RHEUMATOID-ARTHRITIS - INDICATIONS, OPERATIVE TECHNIQUE, AND RESULTS [J].
COVENTRY, MB ;
MINNESOT.R .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (01) :23-48
[7]
STEPPED STAPLE FOR UPPER TIBIAL OSTEOTOMY [J].
COVENTRY, MB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1969, A 51 (05) :1011-&
[8]
DUGDALE TW, 1992, CLIN ORTHOP RELAT R, P248
[9]
Proximal tibia medial open-wedge osteotomy using plates with wedges: early results in 58 cases [J].
Esenkaya, Irfan ;
Elmali, Nurzat .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2006, 14 (10) :955-961
[10]
Franco V, 2002, TECH KNEE SURG, V1, P43