Ultrasensitive near-infrared integrated cavity output spectroscopy technique for detection of CO at 1.57 μm:: new sensitivity limits for absorption measurements in passive optical cavities

被引:76
作者
Engel, Gregory S. [1 ]
Drisdell, Walter S. [1 ]
Keutsch, Frank N. [1 ]
Moyer, Elisabeth J. [1 ]
Anderson, James G. [1 ]
机构
[1] Harvard Univ, Dept Chem, Cambridge, MA 02138 USA
关键词
D O I
10.1364/AO.45.009221
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A robust absorption spectrometer using the off-axis integrated cavity output spectroscopy (ICOS) technique in a passive cavity is presented. The observed sensitivity, conceptually the detection threshold for the absorption cross section (cm) multiplied by the concentration (cm(-3)) and normalized by the averaging time, is measured to be 1.9 x 10(-12) (1/cm root Hz). This high sensitivity arises from using the optical cavity to amplify the observed path length in the spectrometer while avoiding cavity resonances by careful design of the spot pattern within the cavity. The instrument is ideally suited for routine monitoring of trace gases in the near-infrared region. A spectrum showing ambient carbon monoxide at 1.57 mu m is presented.
引用
收藏
页码:9221 / 9229
页数:9
相关论文
共 22 条
[1]   MIRROR REFLECTOMETER BASED ON OPTICAL CAVITY DECAY TIME [J].
ANDERSON, DZ ;
FRISCH, JC ;
MASSER, CS .
APPLIED OPTICS, 1984, 23 (08) :1238-1245
[2]   Cavity ring-down spectroscopy: Experimental schemes and applications [J].
Berden, G ;
Peeters, R ;
Meijer, G .
INTERNATIONAL REVIEWS IN PHYSICAL CHEMISTRY, 2000, 19 (04) :565-607
[3]  
ENGEL GS, 2004, THESIS HARVARD U
[4]   Cavity enhanced absorption and cavity enhanced magnetic rotation spectroscopy [J].
Engeln, R ;
Berden, G ;
Peeters, R ;
Meijer, G .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (11) :3763-3769
[5]   SENSITIVE MEASUREMENT OF PHOTON LIFETIME AND TRUE REFLECTANCES IN AN OPTICAL CAVITY BY A PHASE-SHIFT METHOD [J].
HERBELIN, JM ;
MCKAY, JA ;
KWOK, MA ;
UEUNTEN, RH ;
UREVIG, DS ;
SPENCER, DJ ;
BENARD, DJ .
APPLIED OPTICS, 1980, 19 (01) :144-147
[6]   The superposition principle and cavity ring-down spectroscopy [J].
Lehmann, KK ;
Romanini, D .
JOURNAL OF CHEMICAL PHYSICS, 1996, 105 (23) :10263-10277
[7]  
LEHMANN KK, 2003, COMMUNICATION MAY
[8]   SWEPT-FREQUENCY INDUCED OPTICAL CAVITY RINGING [J].
LI, ZY ;
BENNETT, RGT ;
STEDMAN, GE .
OPTICS COMMUNICATIONS, 1991, 86 (01) :51-57
[9]   COHERENT CAVITY RING DOWN SPECTROSCOPY [J].
MEIJER, G ;
BOOGAARTS, MGH ;
JONGMA, RT ;
PARKER, DH ;
WODTKE, AM .
CHEMICAL PHYSICS LETTERS, 1994, 217 (1-2) :112-116
[10]   Effects of laser phase noise on the injection of a high-finesse cavity [J].
Morville, J ;
Romanini, D ;
Chenevier, M ;
Kachanov, A .
APPLIED OPTICS, 2002, 41 (33) :6980-6990