Puncture resistance and tensile strength of skin simulants

被引:113
作者
Ankersen, J
Birkbeck, AE
Thomson, RD
Vanezis, P
机构
[1] Univ Glasgow, Dept Mech Engn, Ballist & Impact Grp, Glasgow G12 8QQ, Lanark, Scotland
[2] Univ Glasgow, Dept Forens Med & Sci, Glasgow G12 8QQ, Lanark, Scotland
关键词
skin simulants; knife; stabbing; penetration;
D O I
10.1243/0954411991535103
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
This study aims ultimately to quantify the force needed to penetrate human tissue. The results will reduce the subjectivity of expert opinion in stabbing incidents. They will also aid clinicians in assessing the severity of injury and help prevent the unnecessary deaths which can occur when this is not fully appreciated. Tensile tests were performed to identify suitable skin simulants with synthetic chamois and pigskin as candidate materials. Quasi-static penetration experiments were also performed in which a knife blade penetrated a skin simulant target. Pigskin was found to be much stronger than chamois under tensile load yet the puncture resistance was almost identical for the two materials.
引用
收藏
页码:493 / 501
页数:9
相关论文
共 19 条
[1]
Ankersen J., 1998, Technol Law Insur, V3, P125, DOI [10.1080/135993798349523, DOI 10.1080/135993798349523]
[2]
Backer S., 1960, Text Res J, V30, P704
[3]
CALVANO NJ, 1993, 4895 NISTIR US DEP J
[4]
DALY CH, 1966, THESIS U STRATHCLYDE
[5]
Finlay J. B, 1973, PERSPECTIVES BIOMEDI, P165
[6]
Fung Y. C., 1993, BIOMECHANICS MECH PR
[7]
STAB WOUND DYNAMICS - RECORDING TECHNIQUE FOR USE IN MEDICO-LEGAL INVESTIGATIONS [J].
GREEN, MA .
JOURNAL OF THE FORENSIC SCIENCE SOCIETY, 1978, 18 (3-4) :161-163
[8]
HETHERINGTON JG, 1995, INT J IMPACT ENG, V18, P319
[9]
JANSEN L H, 1958, Dermatologica, V117, P252
[10]
JANSEN L. H., 1958, DERMATOLOGICA [BASEL], V117, P65