Coherence imaging by use of a Newton rings sampling function

被引:105
作者
Podoleanu, AG
Dobre, GM
Webb, DJ
Jackson, DA
机构
[1] Applied Optics Group, Physics Laboratory, University of Kent, Canterbury
关键词
D O I
10.1364/OL.21.001789
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We show that, with suitable optics in the arm of a Michelson interferometer, orthogonal galvo-scanning mirrors build a sampling function in the form of Newton rings when the two interferometer arms are matched. Using a low-coherence source, one can obtain transversal depth-resolved images. A fast display procedure using a storage oscilloscope was devised based on this method. (C) 1996 Optical Society of America
引用
收藏
页码:1789 / 1791
页数:3
相关论文
共 5 条
  • [1] HIGH-RESOLUTION OPTICAL COHERENCE TOMOGRAPHIC IMAGING USING A MODE-LOCKED TI-AL2O3 LASER SOURCE
    BOUMA, B
    TEARNEY, GJ
    BOPPART, SA
    HEE, MR
    BREZINSKI, ME
    FUJIMOTO, JG
    [J]. OPTICS LETTERS, 1995, 20 (13) : 1486 - 1488
  • [2] FEMTOSECOND TRANSILLUMINATION TOMOGRAPHY IN THICK TISSUES
    HEE, MR
    IZATT, JA
    SWANSON, EA
    FUJIMOTO, JG
    [J]. OPTICS LETTERS, 1993, 18 (13) : 1107 - 1109
  • [3] IZATT JA, 1993, P SOC PHOTO-OPT INS, V1877, P136, DOI 10.1117/12.147520
  • [4] LEUNG AF, 1991, AM J PHYS, V59, P663
  • [5] IN-VIVO RETINAL IMAGING BY OPTICAL COHERENCE TOMOGRAPHY
    SWANSON, EA
    IZATT, JA
    HEE, MR
    HUANG, D
    LIN, CP
    SCHUMAN, JS
    PULIAFITO, CA
    FUJIMOTO, JG
    [J]. OPTICS LETTERS, 1993, 18 (21) : 1864 - 1866