Characteristics of subtractive anodic stripping voltammetry of Pb and Cd at silver and gold electrodes

被引:115
作者
Bonfil, Y [1 ]
Brand, M [1 ]
Kirowa-Eisner, E [1 ]
机构
[1] Tel Aviv Univ, Raymond & Beverly Sackler Fac Exact Sci, Sch Chem, IL-69978 Tel Aviv, Israel
关键词
subtractive anodic stripping voltammetry; silver electrode; gold electrode; lead; cadmium; underpotential deposition; trace analysis;
D O I
10.1016/S0003-2670(02)00489-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Silver and gold electrodes are useful for the quantitative determination of lead and cadmium with subtractive anodic stripping voltammetry (SASV). The use of SASV is essential for achieving good separation between the two peaks, to eliminate the interference of nitrates when cadmium is present and to allow analysis at very low concentrations without the removal of oxygen. The deposition and dissolution of Pb2+ and Cd2+ proceed at underpotential (UPD) on both electrodes. The UPD properties of the deposits are the main factor determining the analytical characteristics of the ASV method and are strongly affected by the type and concentration of the electrolyte. The effects of anions (Cl-, Br-, SO42-, NO3-) and acids (HNO3, HClO4, H2SO4, HCl) are shown. The two electrodes complement each other and, in addition, enable the qualitative identification of Pb2+ and Cd2+, since the peaks appear in opposite order on the two electrodes. Analysis of mixtures of the two analytes is restricted on gold but not on silver. At gold the two peaks overlap: (i) at concentrations of cadmium higher than 250 nM at deposition times greater than 30 s, (ii) in the presence of copper at concentrations higher than 1 muM, and (iii) in the presence of Triton X-100 at concentrations above 10 mg/l. The repeatability at 10 nM analyte is better than 2.5%. The detection limits for Pb2+ and Cd2+ at 120 s deposition time and 3500 rpm rotation rate are: dl(Pb/Ag) = 0.04 nM; dl(Cd/Ag) = 0.7 nM; dl(Pb/Au) = 0.1 nM; dl(Cd/Au) = 0.3 nM. The analysis of lead and cadmium in natural waters has been performed. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:99 / 114
页数:16
相关论文
共 21 条
[1]   IN-LINE ULTRAVIOLET-DIGESTION OF NATURAL-WATER SAMPLES FOR TRACE-METAL DETERMINATION USING AN AUTOMATED VOLTAMMETRIC SYSTEM [J].
ACHTERBERG, EP ;
VAN DEN BERG, CMG .
ANALYTICA CHIMICA ACTA, 1994, 291 (03) :213-232
[2]  
Bagel O, 2001, ELECTROANAL, V13, P100, DOI 10.1002/1521-4109(200102)13:2<100::AID-ELAN100>3.0.CO
[3]  
2-I
[4]   Trace determination of mercury by anodic stripping voltammetry at the rotating gold electrode [J].
Bonfil, Y ;
Brand, M ;
Kirowa-Eisner, E .
ANALYTICA CHIMICA ACTA, 2000, 424 (01) :65-76
[5]  
Bonfil Y, 2000, REV ANAL CHEM, V19, P201
[6]   Determination of sub-μg 1-1 concentrations of copper by anodic stripping voltammetry at the gold electrode [J].
Bonfil, Y ;
Brand, M ;
Kirowa-Eisner, E .
ANALYTICA CHIMICA ACTA, 1999, 387 (01) :85-95
[7]   Determination of nanomolar concentrations of lead and cadmium by anodic-stripping voltammetry at the silver electrode [J].
Bonfil, Y ;
Kirowa-Eisner, E .
ANALYTICA CHIMICA ACTA, 2002, 457 (02) :285-296
[8]   The silver electrode in square-wave anodic stripping voltammetry. Determination of Pb2+ without removal of oxygen [J].
Brand, M ;
Eshkenazi, I ;
KirovaEisner, E .
ANALYTICAL CHEMISTRY, 1997, 69 (22) :4660-4664
[9]   Anodic stripping voltammetry of lead and cadmium using a mercury film electrode and thiocyanate [J].
Fischer, E ;
van den Berg, CMG .
ANALYTICA CHIMICA ACTA, 1999, 385 (1-3) :273-280
[10]   Nitrate reduction catalyzed by underpotentially deposited Cd on Au(111): Identification of the electroactive surface structure [J].
Hsieh, SJ ;
Gewirth, AA .
LANGMUIR, 2000, 16 (24) :9501-9512