The accuracy of measurements of three-dimensional computed tomography reconstructions

被引:21
作者
Covino, SW
Mitnick, RJ
Shprintzen, RJ
Cisneros, GJ
机构
[1] ALBERT EINSTEIN COLL MED,MONTEFIORE MED CTR,DEPT DENT,DIV ORTHODONT,BRONX,NY 10467
[2] ALBERT EINSTEIN COLL MED,MONTEFIORE MED CTR,DIV NEURORADIOL,BRONX,NY 10467
[3] ALBERT EINSTEIN COLL MED,MONTEFIORE MED CTR,CTR CRANIOFACIAL DISORDERS,BRONX,NY 10467
关键词
D O I
10.1016/S0278-2391(96)90397-3
中图分类号
R78 [口腔科学];
学科分类号
1003 [口腔医学];
摘要
Purpose: The purpose of this study was to evaluate the accuracy and reproducibility of linear measurements obtained from three-dimensional reconstructions of computed tomography (CT) scans. Materials ana Methods: Ten rectangular acrylic blocks were prepared with titanium molybdenum alloy (TMA) markers spaced from 1 to IO mm, respectively. A plastic sphere was prepared with 10 sets of TMA markers spaced at variable intervals of 1 to 10 mm, Each object was scanned three times at 3-mm slice thicknesses and 1.5 mm with 0.5 mm overlap slice thicknesses, as well as positioned in the GT scanner in two different directions (perpendicular and parallel) to the scanning beam. Intermarker distances of the reconstructed objects were then measured using the measurement tool of the MediCAD software and compared with measurements taken by hand with a vernier caliper. Results. Using the 3-mm cut protocol, the data indicated that inconsistency exists between intermarker distance in the scans when the rectangular objects were scanned parallel to the scanning beam. This finding was not seen using the 1.5-mm with 0.5-mm overlap slice thickness protocol, The intermarker distances for objects scanned perpendicular to the scanning beam were consistent but subject to demagnification in the range of 17% to 20% for both scanning protocols, Conclusion: The orientation of the object to the scanning beam and slice thickness protocol appear to have an impact on the accuracy and variability of linear measurements taken in the x, y, z axes.
引用
收藏
页码:982 / 990
页数:9
相关论文
共 21 条
[1]
AMES JR, 1980, J ORAL SURG, V38, P145
[2]
EFFECTS OF RIGID FIXATION DEVICE COMPOSITION ON 3-DIMENSIONAL COMPUTED AXIAL-TOMOGRAPHY IMAGING - DIRECT MEASUREMENTS ON A PIG MODEL [J].
BARONE, CM ;
EISIG, S ;
WALLACH, S ;
MEDNICK, R .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1994, 52 (07) :737-740
[3]
ESTIMATION OF MAXILLARY ALVEOLAR CLEFT VOLUME BY 3-DIMENSIONAL CT [J].
BRADRICK, JP ;
SMITH, AS ;
OHMAN, JC ;
INDRESANO, AT .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (06) :994-996
[4]
DEMARINO DP, 1986, ARCH OTOLARYNGOL, V112, P146
[5]
3-DIMENSIONAL IMAGING [J].
FISHMAN, EK ;
MAGID, D ;
NEY, DR ;
CHANEY, EL ;
PIZER, SM ;
ROSENMAN, JG ;
LEVIN, DN ;
VANNIER, MW ;
KUHLMAN, JE ;
ROBERTSON, DD .
RADIOLOGY, 1991, 181 (02) :321-337
[6]
FUJII N, 1981, J ORAL SURG, V39, P735
[7]
GLOVER GH, 1980, MED PHYSL, V3, P7
[8]
CT OF DRY SKULLS WITH CRANIOFACIAL DEFORMITIES - ACCURACY OF 3-DIMENSIONAL RECONSTRUCTION [J].
HEMMY, DC ;
TESSIER, PL .
RADIOLOGY, 1985, 157 (01) :113-116
[9]
COMPUTED TOMOGRAPHY OF THORAX [J].
JOST, RG ;
SAGEL, SS ;
STANLEY, RJ ;
LEVITT, RG .
RADIOLOGY, 1978, 126 (01) :125-136
[10]
A METHOD FOR 3-DIMENSIONAL IMAGE REFORMATION FOR QUANTITATIVE CEPHALOMETRIC ANALYSIS [J].
MATTESON, SR ;
BECHTOLD, W ;
PHILLIPS, C ;
STAAB, EV .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1989, 47 (10) :1053-1061