Determination of complex formation constants of lipophilic neutral ionophores in solvent polymeric membranes with segmented sandwich membranes

被引:183
作者
Mi, YM [1 ]
Bakker, E [1 ]
机构
[1] Auburn Univ, Dept Chem, Auburn, AL 36849 USA
关键词
D O I
10.1021/ac9905930
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A potentiometric method to determine ionophore complex formation constants in solvent polymeric membrane phases, proposed originally by Russian researchers, is critically evaluated and compared to other established methods. It requires membrane potential measurements on two-layer sandwich membranes, where only one side contains the ionophore. The resulting initial membrane potential reflects the ion activity ratio at both aqueous phase-membrane interfaces and can be conveniently used to calculate complex formation constants in situ. This method is potentially useful, since it does not require the use of a reference ion or second ionophore in the measurement. In this paper, the five ionophores valinomycin, BME-44, ETH 2120, tert-butylcalix[4]arene tetraethyl ester, and S,S'-methylenebis(diisobutyldithiocarbamate) are characterized in poly(vinyl chloride) (PVC) plasticized with dioctyl sebacate (DOS) and compared with other established methods. The resulting formation constants correspond well to literature values. The influence of varying membrane concentrations and different anionic site additives is studied and found to be relatively small. Experiments are also performed with and without lipophilic inert electrolytes and with ionophore-free sandwich membranes to illustrate the effect of ion pairing and the membrane internal diffusion potential on the response of such sandwich membranes. These experiments suggest that ions are completely associated in PVC-DOS membranes, but that such ion pairs are rather nonspecific. Diffusion potentials seem to play a minor role with these systems. The results are explained with theory. This work. indicates that the characterization of electrically charged ionophores, anion-selective ionophores, and ionophores in membrane matrixes other than PVC plasticized with DOS may now be experimentally accessible.
引用
收藏
页码:5279 / 5287
页数:9
相关论文
共 39 条
[1]   PROPERTIES OF PVC BASED MEMBRANES USED IN ION-SELECTIVE ELECTRODES [J].
ARMSTRONG, RD ;
HORVAI, G .
ELECTROCHIMICA ACTA, 1990, 35 (01) :1-7
[2]   Determination of unbiased selectivity coefficients of neutral carrier-based cation-selective electrodes [J].
Bakker, E .
ANALYTICAL CHEMISTRY, 1997, 69 (06) :1061-1069
[3]   LIPOPHILICITY OF TETRAPHENYLBORATE DERIVATIVES AS ANIONIC SITES IN NEUTRAL CARRIER-BASED SOLVENT POLYMERIC MEMBRANES AND LIFETIME OF CORRESPONDING ION-SELECTIVE ELECTROCHEMICAL AND OPTICAL SENSORS [J].
BAKKER, E ;
PRETSCH, E .
ANALYTICA CHIMICA ACTA, 1995, 309 (1-3) :7-17
[4]   OPTIMUM COMPOSITION OF NEUTRAL CARRIER BASED PH ELECTRODES [J].
BAKKER, E ;
XU, AP ;
PRETSCH, E .
ANALYTICA CHIMICA ACTA, 1994, 295 (03) :253-262
[5]   APPLICABILITY OF THE PHASE-BOUNDARY POTENTIAL MODEL TO THE MECHANISTIC UNDERSTANDING OF SOLVENT POLYMERIC MEMBRANE-BASED ION-SELECTIVE ELECTRODES [J].
BAKKER, E ;
NAGELE, M ;
SCHALLER, U ;
PRETSCH, E .
ELECTROANALYSIS, 1995, 7 (09) :817-822
[6]   SYNTHESIS AND CHARACTERIZATION OF NEUTRAL HYDROGEN ION-SELECTIVE CHROMOIONOPHORES FOR USE IN BULK OPTODES [J].
BAKKER, E ;
LERCHI, M ;
ROSATZIN, T ;
RUSTERHOLZ, B ;
SIMON, W .
ANALYTICA CHIMICA ACTA, 1993, 278 (02) :211-225
[7]   Potentiometric determination of effective complex formation constants of lipophilic ion carriers within ion-selective electrode membranes [J].
Bakker, E ;
Pretsch, E .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1997, 144 (05) :L125-L127
[8]   Ion-selective electrodes based on two competitive ionophores for determining effective stability constants of ion-carrier complexes in solvent polymer membranes [J].
Bakker, E ;
Pretsch, E .
ANALYTICAL CHEMISTRY, 1998, 70 (02) :295-302
[9]   DETERMINATION OF COMPLEX-FORMATION CONSTANTS OF NEUTRAL CATION-SELECTIVE IONOPHORES IN SOLVENT POLYMERIC MEMBRANES [J].
BAKKER, E ;
WILLER, M ;
LERCHI, M ;
SEILER, K ;
PRETSCH, E .
ANALYTICAL CHEMISTRY, 1994, 66 (04) :516-521
[10]   Selectivity of carrier-based ion-selective electrodes: Is the problem solved? [J].
Bakker, E .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1997, 16 (05) :252-260