Influence of mechanical behavior on the wear of 4 clinically relevant polymeric biomaterials in a hip simulator

被引:70
作者
Edidin, AA [1 ]
Kurtz, SM [1 ]
机构
[1] Stryker Howmed Osteon, Allendale, NJ 07401 USA
关键词
ultra-high molecular weight polyethylene (UHMWPE; GUR; 1050; RCH; 1000); polyoxymethylene; polyacetal (polyoxymethylene [Delrin]); polytetrafluoroethylene (PTFE [Teflon]); high-density polyethylene (HDPE); wear; hip simulator; small punch test; elastic modulus; contact stress; large-deformation mechanical properties;
D O I
10.1016/S0883-5403(00)90647-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The elastic and large-deformation mechanical behavior of 4 materials with known clinical performance was examined and correlated with the wear behavior in a hip simulator. Acetabular liners of a commercially available design were machined from ultra-high molecular weight polyethylene (UHMWPE), high-density polyethylene (HDPE), polytetrafluoroethylene (PTFE), and polyacetal and wear tested in a multidirectional hip joint simulator. Elastic and large-deformation mechanical behavior was directly measured from the wear-tested liners using the small punch test. The finite element method was used to compute elastic modulus from the measured small punch test initial stiffness, and the contact stress for the liners was calculated using the theory of elasticity solution. Positive, statistically significant correlations were observed between the hip simulator wear rate and the initial peak load, ultimate load, and work to failure from the small punch test. Negative correlations were observed between the wear rate and the elastic modulus and contact stress. The results of this study support the hypothesis that the large-deformation mechanical behavior of a polymer plays a greater role in the wear mechanisms prevalent in total hip replacements than the elastic behavior.
引用
收藏
页码:321 / 331
页数:11
相关论文
共 43 条
[1]   MECHANICAL FACTORS IN LOOSENING OF CHRISTIANSEN AND CHARNLEY ARTHROPLASTIES [J].
ALHO, A ;
SOREIDE, O ;
BJERSAND, AJ .
ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (03) :261-266
[2]  
ALHO A, 1990, ACTA ORTHOP SCAND, V61, P7
[3]   THE EFFECT OF CONFORMITY, THICKNESS, AND MATERIAL ON STRESSES IN ULTRAHIGH MOLECULAR-WEIGHT COMPONENTS FOR TOTAL JOINT REPLACEMENT [J].
BARTEL, DL ;
BICKNELL, VL ;
WRIGHT, TM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (07) :1041-1051
[4]   THE EFFECT OF CONFORMITY AND PLASTIC THICKNESS ON CONTACT STRESSES IN METAL-BACKED PLASTIC IMPLANTS [J].
BARTEL, DL ;
BURSTEIN, AH ;
TODA, MD ;
EDWARDS, DL .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1985, 107 (03) :193-199
[5]  
Bragdon C R, 1996, Proc Inst Mech Eng H, V210, P157, DOI 10.1243/PIME_PROC_1996_210_408_02
[6]  
CHARNLEY J, 1970, CLIN ORTHOP RELAT R, P7
[7]  
CHARNLEY J, 1963, LANCET, V2, P1379
[8]  
CHARNLEY J, 1961, LANCET, V1, P1129
[9]  
Charnley J, 1968, Triangle, V8, P211
[10]  
CHARNLEY J, 1975, CLIN ORTHOP RELAT R, P170