Flooding of gas-solids countercurrent flow in fluidized beds

被引:23
作者
Bi, HT
Cui, HP
Grace, J
Kern, A
Lim, CJ
Rusnell, D
Song, XQ
McKnight, C
机构
[1] Syncrude Canada Ltd, Ft McMurray, AB T9H 3H5, Canada
[2] Univ British Columbia, Dept Chem & Biol Engn, Vancouver, BC V6T 1Z4, Canada
[3] Syncrude Res Ctr, Edmonton, AB T6N 1H4, Canada
关键词
D O I
10.1021/ie030772e
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Flooding experiments were carried out in a semicircular pilot-scale cold model of Syncrude's two fluid cokers. This unit circulates solids downward through a stripper zone and externally back to the top of the vessel, facilitating countercurrent gas/solid contacting. The onset of flooding for FCC particles was determined by analysis of differential pressure signals, supported by visual observations. The solids circulation flux at flooding increased with decreasing superficial gas velocity, with increasing fractional open area, with increasing slot width between adjacent baffles, and with decreasing baffle top included angle. A semiempirical model gives predictions of the onset of flooding that are in good agreement with both cold-flow model results and available commercial data.
引用
收藏
页码:5611 / 5619
页数:9
相关论文
共 14 条
[1]  
Bi HT, 1996, INT J MULTIPHAS FLOW, V22, P1, DOI 10.1016/S0301-9322(96)90003-8
[2]  
Clift R., 1978, BUBBLES DROPS PARTIC
[3]  
Harrison D, 1963, FLUIDISED PARTICLES
[4]  
Knapper B., 2002, CIRCULATING FLUIDIZE, P263
[5]  
Kwauk M., 1963, Scientia Sinica, V12, P587
[6]  
Laguerie C., 1995, FLUIDIZATION, VVIII, P491
[7]  
McKeen T, 2003, INT J CHEM REACT ENG, V1
[8]  
PAPA G, 1995, CHEM ENG PROG, V91, P32
[9]  
SENIOR RC, 1998, FLUIDIZATION, V4, P25
[10]  
SILVEY FC, 1966, CHEM ENG PROG, V62, P68