Three-dimensional magnetic resonance coronary angiography using a new blood pool contrast agent: Initial experience

被引:10
作者
Bedaux, WLF
Hofman, MBM
Wielopolski, PA
de Cock, CC
Hoffmann, V
Oudkerk, M
de Feyter, PJ
van Rossum, AC
机构
[1] Vrije Univ Amsterdam, Med Ctr, Dept Cardiol, NL-1081 HV Amsterdam, Netherlands
[2] VU Univ, Med Ctr, Dept Clin Phys & Informat, Amsterdam, Netherlands
[3] Univ Rotterdam Hosp, Rotterdam, Netherlands
[4] Nycomed Amersham, Munich, Germany
关键词
intravascular contrast agent; magnetic resonance imaging; coronary angiography; coronary artery disease;
D O I
10.1081/JCMR-120003953
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The aim of this feasibility study was to assess the effect of a new blood pool contrast agent on magnetic resonance coronary angiography (MRCA) in patients suspected of having coronary artery disease. Methods: Nine patients referred for diagnostic x-ray coronary, angiography in the evaluation of chest pain underwent MRCA using a thin-slab three-dimensional (3D) breath-hold segmented gradient echo technique at 1.5T before and after intravenous administration of feruglose, a new blood pool contrast agent. Results: A total of 36 coronary arteries, including 15 stenoses were evaluated. Overall agreement of visually assessed stenoses > 50% was 86%. The mean signal-to-noise ratio in the left anterior descending artery (LAD) did not change significantly after contrast administration, a relative improvement of 1.2 +/- 0.4 (p = 0.1), whereas the mean contrast-to-noise ratio of blood to myocardium improved by 3 +/- 2 (p = 0.01). Conclusion: A thin-slab 3D breath-hold scan combined with feruglose allows rapid localization and coverage of the proximal coronary arteries.
引用
收藏
页码:273 / 282
页数:10
相关论文
共 26 条
  • [1] *AD HOC COMM GRAD, 1975, CIRCULATION, V51, P5
  • [2] 2-DIMENSIONAL CORONARY MR-ANGIOGRAPHY - ANALYSIS OF INITIAL CLINICAL-RESULTS
    DUERINCKX, AJ
    URMAN, MK
    [J]. RADIOLOGY, 1994, 193 (03) : 731 - 738
  • [3] CORONARY-ARTERIES - BREATH-HOLD MR ANGIOGRAPHY
    EDELMAN, RR
    MANNING, WJ
    BURSTEIN, D
    PAULIN, S
    [J]. RADIOLOGY, 1991, 181 (03) : 641 - 643
  • [4] Coronary arteries: Breath-hold, gadolinium-enhanced, three-dimensional MR angiography
    Goldfarb, JW
    Edelman, RR
    [J]. RADIOLOGY, 1998, 206 (03) : 830 - 834
  • [5] HAASKE EM, 1999, MAGNETIC RESONANCE I
  • [6] Hendrick R. E., 1992, MAGNETIC RESONANCE I, V1, P109
  • [7] Hofman MBM, 1999, MAGN RESON MED, V41, P360, DOI 10.1002/(SICI)1522-2594(199902)41:2<360::AID-MRM21>3.0.CO
  • [8] 2-C
  • [9] HOFMAN MBM, 1995, J COMPUT ASSIST TOMO, V19, P56
  • [10] High-resolution magnetic resonance coronary angiography of the entire heart using a new blood-pool agent, NC100150 injection: Comparison with invasive X-ray angiography in pigs
    Johansson, LO
    Nolan, MM
    Taniuchi, M
    Fischer, SE
    Wickline, SA
    Lorenz, CH
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 1999, 1 (02) : 139 - 143