Electrocardiogram artifacts caused by deep brain stimulation

被引:26
作者
Constantoyannis, C
Heilbron, B
Honey, CR
机构
[1] Univ British Columbia, Div Neurosurg, Vancouver, BC V5Z 4E5, Canada
[2] Univ British Columbia, Div Cardiol, Vancouver, BC V5Z 4E5, Canada
关键词
D O I
10.1017/S0317167100003425
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Deep brain stimulation (DBS) is increasingly used to treat a variety of neurological conditions (e.g. movement disorders and chronic pain). This prospective study was designed to detect electrocardiogram (ECG) artifacts induced by deep brain stimulation and to investigate which factors (patient disease, electrode position within the brain or type of stimulation) produced these artifacts. Methods: Twelve patients (four women, eight men) with deep brain stimulators were enrolled in the study. Patients were selected to represent the common indications for DBS (Parkinson's disease, tremor, dystonia), the common electrode locations (pallidum, thalamus, subthalamic nucleus) and the two types of stimulation (monopolar, bipolar). Patients had one ECG with the DBS turned 'on' and another with the DBS turned 'off'. The ECGs were then randomized and read by a cardiologist blinded to the status of the patient and DBS and artifacts were noted to be either present or absent. Results: The six patients using monopolar stimulation all had artifacts on their electrocardiograms. These artifacts were severe enough to interfere with ECG interpretation. There were no artifacts detected in the six patients using bipolar stimulation. Electrode location and patient disease appeared to have no effect on ECG artifact. Conclusions: Deep brain stimulation can cause ECG artifacts when monopolar settings are used. These artifacts are not present with bipolar settings or when the DBS is turned 'off'. Knowledge of these potential ECG artifacts and how to avoid them is essential to facilitate accurate ECG interpretation.
引用
收藏
页码:343 / 346
页数:4
相关论文
共 13 条
[1]
BEBABID A, 1998, MOV DISORD S3, V13, P119
[2]
LONG-TERM SUPPRESSION OF TREMOR BY CHRONIC STIMULATION OF THE VENTRAL INTERMEDIATE THALAMIC NUCLEUS [J].
BENABID, AL ;
POLLAK, P ;
GERVASON, C ;
HOFFMANN, D ;
GAO, DM ;
HOMMEL, M ;
PERRET, JE ;
DEROUGEMONT, J .
LANCET, 1991, 337 (8738) :403-406
[3]
BENDOK B, 1998, TXB STEREOTACTIC FUN, P01539
[4]
Thalamic deep brain stimulation for the treatment of tremor due to multiple sclerosis: a prospective study of tremor and quality of life [J].
Berk, C ;
Carr, J ;
Sinden, M ;
Martzke, J ;
Honey, CR .
JOURNAL OF NEUROSURGERY, 2002, 97 (04) :815-820
[5]
KIMBERLEY APS, 1987, ANAESTH INTENS CARE, V15, P358
[6]
Clinical consequences of electrocardiographic artifact mimicking ventricular tachycardia [J].
Knight, BP ;
Pelosi, F ;
Michaud, GF ;
Strickberger, SA ;
Morady, F .
NEW ENGLAND JOURNAL OF MEDICINE, 1999, 341 (17) :1270-1274
[7]
Globus pallidus deep brain stimulation for generalized dystonia: Clinical and PET investigation [J].
Kumar, R ;
Dagher, A ;
Hutchison, WD ;
Lang, AE ;
Lozano, AM .
NEUROLOGY, 1999, 53 (04) :871-874
[8]
Electrical stimulation of the subthalamic nucleus in advanced Parkinson's disease [J].
Limousin, P ;
Krack, P ;
Pollak, P ;
Benazzouz, A ;
Ardouin, C ;
Hoffmann, D ;
Benabid, AL .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (16) :1105-1111
[9]
Multicentre European study of thalamic stimulation in parkinsonian and essential tremor [J].
Limousin, P ;
Speelman, JD ;
Gielen, F ;
Janssens, M .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1999, 66 (03) :289-296
[10]
ECG artifact due to deep brain stimulation [J].
Martin, WA ;
Camenzind, E ;
Burkhard, PR .
LANCET, 2003, 361 (9367) :1431-1431