Comparison of neointimal formation in polymer-free Paclitaxel stents versus stainless stents (from the ASPECT and ELUTES randomized clinical trials)

被引:13
作者
Kaluza, GL
Gershlick, AH
Park, SJ
De Scheerder, I
Chevalier, B
Camenzind, E
Goy, JJ
Missault, L
Reifart, N
Vrints, C
Urban, P
Shim, WH
Ho, DSW
Fearnot, NE
Voorhees, WD
Raizner, AE
机构
[1] Methodist DeBakey Heart Ctr, Houston, TX 77030 USA
[2] Baylor Coll Med, Houston, TX 77030 USA
[3] Univ Hosp, Leicester, Leics, England
[4] Asan Med Ctr, Seoul, South Korea
[5] Univ Hosp Gasthuisberg, Louvain, Belgium
[6] Univ Hosp, Geneva, Switzerland
[7] Ctr Cardiol Nord, St Denis, France
[8] Clin Cecil, Lausanne, Switzerland
[9] Univ Hosp, Geneva, Switzerland
[10] Acad Hosp St Jan, Brugge, Belgium
[11] Kardiol Inst, Bad Soden, Germany
[12] Univ Hosp, Antwerp, Belgium
[13] Hosp La Tour, Geneva, Switzerland
[14] Yonsei Med Ctr, Seoul, South Korea
[15] Univ Hosp, Hong Kong, Hong Kong, Peoples R China
[16] MED Inst, W Lafayette, IN USA
关键词
D O I
10.1016/j.amjcard.2004.03.063
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The investigators examined 326 pairs of angiograms from 2 randomized dose-finding (0.2 to 3.1 mug paclitaxel/mm(2) of stent surface area) clinical trials of polymer-free paclitaxel-eluting stents in de novo lesions (the ASian Paclitaxel-Eluting stent Clinical Trial [ASPECT] and the European evoLUation of Taxol Eluting Stent [ELUTES]). A dose-dependent effect was observed: the largest dose of paclitaxel in the 2 trials resulted in a significantly larger proportion of lesions at follow-up with <10% diameter stenosis (54% vs 16%, p = 0.00012 in ASPECT, 53% vs 21%, p = 0.013 in ELUTES) and with minimal luminal diameter located outside the stent compared with control stents (62% vs 20% in ASPECT, 48% vs 18% in ELUTES; p <0.05). Also, significantly shorter lesion lengths at 6-month follow-up were observed for the doses of 0.7 to 3.1 mug/mm(2) (p<0.03) relative to their respective lengths before the procedure compared with control stents. (C) 2004 by Excerpta Medica, Inc.
引用
收藏
页码:199 / 201
页数:3
相关论文
共 15 条
[1]   Final results of a randomized trial comparing the NIR stent to the Palmaz-Schatz stent for narrowings in native coronary arteries [J].
Baim, DS ;
Cutlip, DE ;
O'Shaughnessy, CD ;
Hermiller, JB ;
Kereiakes, DJ ;
Giambartolomei, A ;
Katz, S ;
Lansky, AJ ;
Fitzpatrick, M ;
Popma, JJ ;
Ho, KKL ;
Leon, MB ;
Kuntz, RE .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 87 (02) :152-156
[2]   Final results of a randomized trial comparing the MULTI-LINK stent with the Palmaz-Schatz stent for narrowings in native coronary arteries [J].
Baim, DS ;
Cutlip, DE ;
Midei, M ;
Linnemeier, TJ ;
Schreiber, T ;
Cox, D ;
Kereiakes, D ;
Popma, JJ ;
Robertson, L ;
Prince, R ;
Lansky, AJ ;
Ho, KKL ;
Kuntz, RE .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 87 (02) :157-162
[3]   Randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for coronary artery lesions [J].
Colombo, A ;
Drzewiecki, J ;
Banning, A ;
Grube, E ;
Hauptmann, K ;
Silber, S ;
Dudek, D ;
Fort, S ;
Schiele, F ;
Zmudka, K ;
Guagliumi, G ;
Russell, ME .
CIRCULATION, 2003, 108 (07) :788-794
[4]   Stent and artery geometry determine intimal thickening independent of arterial injury [J].
Garasic, JM ;
Edelman, ER ;
Squire, JC ;
Seifert, P ;
Williams, MS ;
Rogers, C .
CIRCULATION, 2000, 101 (07) :812-818
[5]   Inhibition of restenosis with a paclitaxel-eluting, polymer-free coronary stent - The European evaLUation of pacliTaxel Eluting Stent (ELUTES) trial [J].
Gershlick, A ;
De Scheerder, I ;
Chevalier, B ;
Stephens-Lloyd, A ;
Camenzind, E ;
Vrints, C ;
Reifart, N ;
Missault, L ;
Goy, JJ ;
Brinker, JA ;
Raizner, AE ;
Urban, P ;
Heldman, AW .
CIRCULATION, 2004, 109 (04) :487-493
[6]   Physiological transport forces govern drug distribution for stent-based delivery [J].
Hwang, CW ;
Wu, D ;
Edelman, ER .
CIRCULATION, 2001, 104 (05) :600-605
[7]   Stented segment length as an independent predictor of restenosis [J].
Kobayashi, Y ;
De Gregorio, J ;
Kobayashi, N ;
Akiyama, T ;
Reimers, B ;
Finci, L ;
Di Mario, C ;
Colombo, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 34 (03) :651-659
[8]   Quantitative angiographic methods for appropriate end-point analysis, edge-effect evaluation, and prediction of recurrent restenosis after coronary brachytherapy with gamma irradiation [J].
Lansky, AJ ;
Dangas, G ;
Mehran, R ;
Desai, KJ ;
Mintz, GS ;
Wu, HS ;
Fahy, M ;
Stone, GW ;
Waksman, R ;
Leon, MB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (02) :274-280
[9]   Coronary restenosis after sirolimus-eluting stent implantation - Morphological description and mechanistic analysis from a consecutive series of cases [J].
Lemos, PA ;
Saia, F ;
Ligthart, JMR ;
Arampatzis, CA ;
Sianos, G ;
Tanabe, K ;
Hoye, A ;
Degertekin, M ;
Daemen, J ;
McFadden, E ;
Hofma, S ;
Smits, PC ;
de Feyter, P ;
van der Giessen, WJ ;
van Domburg, RT ;
Serruys, PW .
CIRCULATION, 2003, 108 (03) :257-260
[10]   Angiographic patterns of in-stent restenosis - Classification and implications for long-term outcome [J].
Mehran, R ;
Dangas, G ;
Abizaid, AS ;
Mintz, GS ;
Lansky, AJ ;
Satler, LF ;
Pichard, AD ;
Kent, KM ;
Stone, GW ;
Leon, MB .
CIRCULATION, 1999, 100 (18) :1872-1878