Beam test results from a fine-sampling quartz fiber calorimeter for electron, photon and hadron detection

被引:51
作者
Akchurin, N
Ayan, S
Bencze, GL
Chikin, K
Cohn, H
Doulas, S
Dumanoglu, I
Eskut, E
Fenyvesi, A
Ferrando, A
Fouz, MC
Ganel, O
Gavrilov, V
Gershtein, Y
Hajdu, C
Iosifidis, J
Josa, MI
Khan, A
Kim, SB
Kolosov, V
Kuleshov, S
Langland, J
Litvintsev, D
Merlo, JP
Molnar, J
Nikitin, A
Onel, Y
Onengut, G
Osborne, D
OzdesKoca, N
Penzo, A
Pesen, E
Podrasky, V
Rosowsky, A
Salico, JM
Sanzeni, C
Sever, R
Silvestri, H
Stolin, V
Sulak, L
Sullivan, J
Ulyanov, A
Uzunian, S
Vesztergombi, G
Wigmans, R
Winn, D
Winsor, R
Yumashev, A
Zalan, P
Zeyrek, M
机构
[1] TEXAS TECH UNIV,DEPT PHYS,LUBBOCK,TX 79409
[2] ITEP,MOSCOW,RUSSIA
[3] FAIRFIELD UNIV,FAIRFIELD,CT 06430
[4] UNIV TRIESTE,TRIESTE,ITALY
[5] IST NAZL FIS NUCL,TRIESTE,ITALY
[6] CIEMAT,E-28040 MADRID,SPAIN
[7] ATOMKI,DEBRECEN,HUNGARY
[8] CUKUROVA UNIV,ADANA,TURKEY
[9] BOSTON UNIV,BOSTON,MA 02215
[10] OAK RIDGE NATL LAB,OAK RIDGE,TN
[11] NPI MOSCOW STATE UNIV,MOSCOW,RUSSIA
[12] KFKI,RMKI,BUDAPEST,HUNGARY
[13] MIDDLE E TECH UNIV,TR-06531 ANKARA,TURKEY
[14] UNIV IOWA,IOWA CITY,IA
关键词
D O I
10.1016/S0168-9002(97)00789-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We present the results of beam tests with high-energy (8-375 GeV) electrons, pions, protons and muons of a sampling calorimeter based on the detection of Cherenkov light produced by shower particles. The detector, a prototype for the very forward calorimeters in the CMS experiment, consists of thin quartz fibers embedded in a copper matrix. Results are given on the light yield of this device, on its energy resolution for electron and hadron detection, and on the signal uniformity and linearity. The signal generation mechanism gives this type of detector unique properties, especially for the detection of hadron showers: narrow, shallow shower profiles and extremely fast signals. These specific properties were measured in detail. The implications for measurements in the high-rate, high-radiation Large Hadron Collider (LHC) environment are discussed.
引用
收藏
页码:202 / 226
页数:25
相关论文
共 22 条
[1]   LATERAL SHOWER PROFILES IN A LEAD SCINTILLATING FIBER CALORIMETER [J].
ACOSTA, D ;
BUONTEMPO, S ;
CALOBA, L ;
DESALVO, R ;
EREDITATO, A ;
FERRARI, R ;
FUMAGALLI, G ;
GOGGI, G ;
HAO, W ;
HENRIQUES, A ;
LINSSEN, L ;
LIVAN, M ;
MAIO, A ;
MONDARDINI, MR ;
ONG, B ;
PAAR, HP ;
PASTORE, F ;
PENNACCHIO, E ;
POGGIOLI, L ;
POLESELLO, G ;
RICCARDI, F ;
RIMOLDI, A ;
SCHEEL, CV ;
SEIXAS, JM ;
SIMON, A ;
SIVERTZ, M ;
SONDEREGGER, P ;
SOUZA, MN ;
THOME, ZD ;
VERCESI, V ;
WANG, Y ;
WIGMANS, R ;
XU, C .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 316 (2-3) :184-201
[2]  
ACOSTA D, 1991, NUCL INSTRUM METH A, V308, P481, DOI 10.1016/0168-9002(91)90062-U
[3]   RESULTS OF PROTOTYPE STUDIES FOR A SPAGHETTI CALORIMETER [J].
ACOSTA, D ;
BUONTEMPO, S ;
CALOBA, L ;
CARIA, M ;
DESALVO, R ;
EREDITATO, A ;
FERRARI, R ;
FRATERNALI, M ;
FUMAGALLI, G ;
GILDEMEISTER, O ;
HARTJES, FG ;
HENKES, TH ;
HENRIQUES, A ;
LINSSEN, L ;
LIVAN, M ;
MAIO, A ;
MAPELLI, L ;
MEIER, KH ;
ONG, B ;
PAAR, HP ;
PASTORE, F ;
PEREIRA, M ;
POGGIOLI, L ;
SCHEEL, CV ;
SEIXAS, JM ;
SIMON, A ;
SIVERTZ, M ;
SONDEREGGER, P ;
SOUZA, MN ;
THOME, ZD ;
VERCESI, V ;
WIGMANS, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 294 (1-2) :193-210
[4]   FLUCTUATIONS IN CALORIMETRY MEASUREMENTS [J].
AMALDI, U .
PHYSICA SCRIPTA, 1981, 23 (04) :409-424
[5]   ANGULAR-DEPENDENCE OF QUARTZ FIBER CALORIMETER RESPONSE [J].
ANZIVINO, G ;
CHAMOROVSKII, Y ;
CONTIN, A ;
DANILOV, M ;
DELLACASA, G ;
DESALVO, R ;
GAVRILOV, V ;
GOLUTVIN, A ;
GORODETZKY, P ;
HELLEBOID, JM ;
ISAEV, V ;
JOHNSON, KF ;
JUILLOT, P ;
KULESHOV, S ;
LACOMMARE, G ;
LAZIC, D ;
LITVINTSEV, D ;
LUNDIN, M ;
MARINO, M ;
MUSSO, A ;
RATNIKOV, F ;
RUSINOV, V ;
STOLIN, V ;
VINOGRADOV, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 360 (1-2) :237-239
[6]   TEST-RESULTS OF AN ELECTROMAGNETIC CALORIMETER WITH 0.5 MM SCINTILLATING FIBERS READOUT [J].
BADIER, J ;
BOUHEMAID, N ;
BUONTEMPO, S ;
BUSSON, P ;
CALOBA, L ;
CATTANEO, P ;
CHARLOT, C ;
CHEKHTMAN, A ;
COUSINOU, MC ;
DAGORET, S ;
DELLACQUA, A ;
EREDITATO, A ;
FERRARI, R ;
FOUCHEZ, D ;
FREDJ, L ;
FUMAGALLI, G ;
GAILLARD, JM ;
GOGGI, G ;
GOMES, A ;
HANSLKOZANECKA, T ;
HENRIQUES, A ;
KOVACS, F ;
LINSSEN, L ;
LIVAN, M ;
LORY, J ;
MAIO, A ;
MICHEL, B ;
MONTAROU, G ;
NACASCH, R ;
NAGY, E ;
PAAR, HP ;
PALLIN, D ;
PENNACCHIO, E ;
PERALTA, L ;
POGGIOLI, L ;
POLESELLO, G ;
RICCARDI, F ;
RIMOLDI, A ;
SEIXAS, JM ;
SIVERTZ, M ;
SOUZA, MN ;
THOME, ZD ;
TISSERANT, S ;
TOME, B ;
VAZEILLE, F ;
VERCESI, V ;
WIGMANS, R ;
ZITOUN, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 337 (2-3) :314-325
[7]   1ST RESULTS ON THE SPHAGHETTI CALORIMETER PROJECTIVE PROTOTYPE [J].
BENCHEIKH, B ;
CONTIN, A ;
DESALVO, R ;
HAO, W ;
WANG, YY ;
XU, C ;
YOU, K .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 315 (1-3) :354-361
[8]   RADIATION TESTING OF OPTICAL FIBERS FOR A HOT-CELL PHOTOMETER [J].
CHESSER, JB .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (03) :307-309
[9]  
*CMS COLL, 1994, 9438 CERN
[10]   Beam test results from the SPAKEBAB electromagnetic calorimeter [J].
Dubois, O ;
Ganel, O ;
Wigmans, R ;
Brower, W ;
Dominguez, A ;
Duba, C ;
Paar, H .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 368 (03) :640-652