Early detection and treatment of hemodialysis access dysfunction

被引:21
作者
Beuter, JJG [1 ]
Lezana, AH [1 ]
Calvo, JH [1 ]
Carriles, RM [1 ]
机构
[1] Hosp Clin San Carlos, Dept Radiol, E-28040 Madrid, Spain
关键词
hemodialysis access dysfunction; early detection; percutaneous treatment;
D O I
10.1007/s002709910006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To assess the usefulness of a program for the early detection of hemodialysis graft dysfunction and the impact on graft survival of percutaneous transluminal angioplasty (PTA) and stent implantation to corner venous stenosis. Methods: A program for the early detection of hemodialysis access graft dysfunction was carried out in 110 patients over a period of 80 months. Detection was based on physical examination, flow rare measurements, venous pressure, and analytical determinations performed at dialysis. The stenoses detected were treated by PTA or PTA plus stent deployment. Survival curves compared primary and assisted patency rates for the different graft types. Results: The most important indicators of dysfunction were increased venous pressure and difficulty in cannulation of the graft. Significant stenoses were revealed by 227 (92.2%) of the 246 fistulography procedures performed. PTA results were satisfactory in 100% of the Thomas grafts, 74% of the Brescia-Cimino (BC) grafts, and 53% of the polytetrafluoroethylene (PTFE) grafts. Technical success rates for stent deployment were 92% for BC grafts and 100% for PTFE grafts, while functional success rates were 96% and 97% respectively, The difference in the primary patency (P1) and assisted patency (AP) values was statistically significant fur all three graft types. There was no significant difference in the patency rates for grafts treated by PTA alone or by PTA and stent deployment. Conclusion: A surveillance program helped prevent graft thrombosis, and intervention as required achieved excellent primary and assisted patency rates. Stent deployment salvaged a considerable number of accesses but did not significantly extend access survival time.
引用
收藏
页码:40 / 46
页数:7
相关论文
共 23 条
[1]   PHYSICAL-EXAMINATION OF AV GRAFTS [J].
BEATHARD, GA .
SEMINARS IN DIALYSIS, 1992, 5 (01) :74-74
[2]   GIANTURCO SELF-EXPANDING STENT IN THE TREATMENT OF STENOSIS IN DIALYSIS ACCESS GRAFTS [J].
BEATHARD, GA .
KIDNEY INTERNATIONAL, 1993, 43 (04) :872-877
[3]   PERCUTANEOUS TRANSVENOUS ANGIOPLASTY IN THE TREATMENT OF VASCULAR ACCESS STENOSIS [J].
BEATHARD, GA .
KIDNEY INTERNATIONAL, 1992, 42 (06) :1390-1397
[4]   THE ROLE OF PERCUTANEOUS ANGIOPLASTY IN THE MANAGEMENT OF CHRONIC-HEMODIALYSIS FISTULAS [J].
GLANZ, S ;
GORDON, DH ;
BUTT, KMH ;
HONG, J ;
LIPKOWITZ, GS .
ANNALS OF SURGERY, 1987, 206 (06) :777-781
[5]   Percutaneous intervention for permanent hemodialysis access: A review [J].
Gray, RJ .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1997, 8 (03) :313-327
[6]   Prospective randomized trial of a metallic intravascular stent in hemodialysis graft maintenance [J].
Hoffer, EK ;
Sultan, S ;
Herskowitz, MM ;
Daniels, ID ;
Sclafani, SJA .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1997, 8 (06) :965-973
[7]   DIALYSIS ACCESS GRAFTS - ANATOMIC LOCATION OF VENOUS STENOSIS AND RESULTS ANGIOPLASTY [J].
KANTERMAN, RY ;
VESELY, TM ;
PILGRAM, TK ;
GUY, BW ;
WINDUS, DW ;
PICUS, D .
RADIOLOGY, 1995, 195 (01) :135-139
[8]  
KUMPE DA, 1998, J VASC INTERV RADIOL, V9, P120
[9]  
*ONT, 1996, REV ESP TRANSPLANTES, V5, P16
[10]  
PEREZJCR, 1989, NEPHRON, V51, P192