The Nordic Trueness Project 2002:: use of reference measurement procedure values in a general clinical chemistry survey

被引:12
作者
Pedersen, MM
Örnemark, U
Rustad, P
Steensland, H
Loikkanen, M
Olafsdóttir, E
Henriksen, GM
Jorgensen, N
Uldall, A
Nordin, G
Nordberg, UR
机构
[1] EQUALIS, SE-75109 Uppsala, Sweden
[2] Herlev Univ Hosp, DEKS, DK-2730 Herlev, Denmark
[3] Furst Med Lab, Oslo, Norway
[4] Ullevaal Univ Hosp, Dept Clin Chem, Oslo, Norway
[5] Labquality, Helsinki, Finland
[6] Iceland Heart Assoc, Heart Prevent Clin & Res Inst, ISLM, Kopavogur, Iceland
[7] Sonderborg Sygehus, Klin Kem Afdeling, Sonderborg, Denmark
关键词
commutability; external quality assurance; frozen serum; lyophilized serum; matrix effects; NORIP; reference measurements; value transfer;
D O I
10.1080/00365510410002805
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Up to 136 laboratories participated in a joint effort to assess the trueness of routine measurements for 14 serum components. An unmodified, fresh-frozen human serum ("IMEP-17 Material 1''), produced for an international inter-laboratory comparison, served as the "master material''. The serum had assigned values of the highest available metrological quality, and is assumed to involve no or negligible commutability problems. The material was used in the assignment of traceable values to two other reference sera, "CAL'' and "X'', through parallel measurements on the three materials according to a common protocol. In this transfer process, uncertainty estimates were provided for all values. The material CAL had been supplied with reference measurement procedure values in 1997, and the two sets of assigned values agreed well. A lyophilized control serum "HK02'' was also included in the routine analysis series. It, too, had assigned values based on reference measurement procedures. Significant matrix effects were found. The project has provided: Assigned traceable values for 14 components in a fresh-frozen serum, available to Nordic laboratories for the coming years as "NFKK reference serum X''. Confirmation of earlier assigned reference measurement procedure values for a number of components in CAL, the main calibrator in the Nordic Reference Interval Project (NORIP). The transferred values will now serve as the primary reference. Evidence of long-term stability (greater than or equal to5 years) of the fresh-frozen serum CAL when stored at -80degreesC. Evidence of substantial matrix effects in the processed serum HK02. The findings should be used to discuss to what extent reference measurement procedure values are useful and cost-efficient for this type of material.
引用
收藏
页码:309 / 319
页数:11
相关论文
共 20 条
[1]  
*BIPM IEC IFCC ISO, 1995, GUID EXPR UNC MEAS
[2]  
BUTTNER J, 1983, J CLIN CHEM CLIN BIO, V21, P885
[3]   Minimally processed fresh frozen human reference sera: preparation, testing, and application to international external quality assurance [J].
Henriksen, GM ;
Pedersen, MM ;
Norgaard, I ;
Blom, M ;
Blou, L ;
Blaabjerg, O ;
Uldall, A .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2004, 64 (04) :293-307
[4]  
*INT ORG STAND, 151952003 ENISO
[5]  
International Organization for Standardization, 175112003 EN ISO
[6]  
*ISO, 1997, 431 ISO 1
[7]  
*ISO DIS, 2002, 13528 ISODIS
[8]  
*LABQUALITY, CLIN CHEM METH GUID
[9]  
ORNEMARK U, 20694 EUR EN
[10]  
ORNEMARK U, 2002, 20243 EUR EN IRMM GE