Experimental behaviour of a steel structure under natural fire

被引:213
作者
Wald, F.
Simoes da Silva, L. [1 ]
Moore, D. B.
Lennon, T.
Chladna, M.
Santiago, A.
Benes, M.
Borges, L.
机构
[1] Czech Tech Univ, Dept Steel Struct, Prague, Czech Republic
[2] Univ Coimbra, Dept Civil Engn, P-3030290 Coimbra, Portugal
[3] BCSA, London, England
[4] Bldg Res Estab, Watford WD2 7JR, England
[5] Slovak Univ Technol Bratislava, Dept Steel Struct, Bratislava, Slovakia
[6] Ecole Polytech Fed Lausanne, Steel Struct Lab, Lausanne, Switzerland
关键词
structural engineering; steel and composite structures; full-scale tests; fire design; structural integrity;
D O I
10.1016/j.firesaf.2006.05.006
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Current design codes for fire resistance of structures are based on isolated member tests subjected to standard fire conditions. Such tests do not reflect the behaviour of a complete building under either normal temperature or fire conditions. Many aspects of behaviour occur due to the interaction between members and cannot be predicted or observed in tests of isolated elements. Performance of real structures subject to real fires is often much better than that predicted from standard tests due to structural continuity and the provision of alternative load paths. This paper reports on the results of a collaborative research project (Tensile membrane action and robustness of structural steel joints under natural fire, European Community FP5 project HPRI-CV 5535) involving the following institutions: Czech Technical University (Czech Republic), University of Coimbra (Portugal), Slovak Technical University (Slovak Republic) and Building Research Establishment (United Kingdom). It consists of an experimental programme to investigate the global structural behaviour of a compartment on the 8-storey steel-concrete composite frame building at the Cardington laboratory during a BRE large-scale fire test, aimed at the examination of the temperature development within the various structural elements, the corresponding (dynamic) distribution of internal forces and the behaviour of the composite slab, beams, columns and connections. (C) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:509 / 522
页数:14
相关论文
共 26 条
[1]  
[Anonymous], 2003, PREN199312 CEN
[2]  
BENES M, 2002, P 3 EUR C STEEL STRU, P1401
[3]  
Bravery P. N. R., 1993, CARDINGTON LARGE BUI, P158
[4]  
*CEN, 2002, PREN199112 CEN
[5]  
*ECSC, 2002, 7210 PA ECSC, P108
[6]  
GENES DC, 1982, AM SOC CIV ENG C LAS
[7]  
KRUPPA J, 1982, FIRE SAFETY J, V4, P247
[8]   Possible 'panel instability' in composite deck floor systems under fire [J].
Lamont, S ;
Usmani, AS .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2003, 59 (11) :1397-1433
[9]   THE TEMPERATURES ATTAINED BY UNPROTECTED STRUCTURAL STEELWORK IN EXPERIMENTAL NATURAL FIRES [J].
LATHAM, DJ ;
KIRBY, BR ;
THOMSON, G .
FIRE SAFETY JOURNAL, 1987, 12 (02) :139-152
[10]  
Latham DJ, 1987, STEEL CONSTR TODAY, V1, P49