Optimization of static field homogeneity in human brain using diamagnetic passive shims

被引:77
作者
Wilson, JL [1 ]
Jenkinson, M [1 ]
Jezzard, P [1 ]
机构
[1] Univ Oxford, John Radcliffe Hosp, FMRIB Ctr, Dept Clin Neurol, Oxford OX3 9DU, England
关键词
shimming; susceptibility artifact; fMRI; diamagnetic; inferior frontal cortex;
D O I
10.1002/mrm.10298
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
These preliminary studies demonstrate that static field inhomogeneity in the human inferior frontal cortex (IFC) is significantly diminished through placement of a small amount of strongly diamagnetic material in the roof of the mouth. As a result, susceptibility-related image artifacts in this region, as observed in blood oxygen level dependent (BOLD) functional MRI (fMRI), are considerably decreased without compromising the spatial or temporal resolution of the study. Simulations of the static field utilizing perturbation theory are shown, which support the experimental results. The limitations and possible future developments of the technique are described. The application of diamagnetic passive shimming on other regions of the brain is also discussed. Routine use of the proposed method within fMRI studies is practicable through subject-specific optimization of the technique utilizing the simulation algorithm. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:906 / 914
页数:9
相关论文
共 38 条
[1]   HIGH-SPEED SPIRAL-SCAN ECHO PLANAR NMR IMAGING .1. [J].
AHN, CB ;
KIM, JH ;
CHO, ZH .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1986, 5 (01) :2-7
[2]   Radio frequency magnetic field mapping of a 3 tesla birdcage coil: Experimental and theoretical dependence on sample properties [J].
Alecci, M ;
Collins, CM ;
Smith, MB ;
Jezzard, P .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (02) :379-385
[3]   MULTI-PLANAR IMAGE-FORMATION USING NMR SPIN ECHOES [J].
MANSFIELD, P .
JOURNAL OF PHYSICS C-SOLID STATE PHYSICS, 1977, 10 (03) :L55-L58
[4]   Dynamic shim updating: A new approach towards optimized whole brain shimming [J].
Blamire, AM ;
Rothman, DL ;
Nixon, T .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (01) :159-165
[5]   MAGNETIC-FIELD SHIMMING BY FOURIER-ANALYSIS [J].
BRATEMAN, L ;
BOWMAN, TT ;
DONSTRUP, S ;
SCOTT, KN .
MAGNETIC RESONANCE IN MEDICINE, 1988, 6 (04) :459-473
[6]   HEATING EFFECTS OF METALLIC IMPLANTS BY MRI EXAMINATIONS [J].
BUCHLI, R ;
BOESIGER, P ;
MEIER, D .
MAGNETIC RESONANCE IN MEDICINE, 1988, 7 (03) :255-261
[7]   Cancellation of metal-induced MRI artifacts with dual-component paramagnetic and diamagnetic material: Mathematical modelization and experimental verification [J].
Chauvel, B ;
Cathelineau, G ;
Balac, S ;
Lecerf, J ;
deCertaines, JD .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (06) :936-938
[8]   Compensation of susceptibility-induced BOLD sensitivity losses in echo-planar fMRI Imaging [J].
Deichmann, R ;
Josephs, O ;
Hutton, C ;
Corfield, DR ;
Turner, R .
NEUROIMAGE, 2002, 15 (01) :120-135
[9]   Susceptibility-induced loss of signal: Comparing PET and fMRI on a semantic task [J].
Devlin, JT ;
Russell, RP ;
Davis, MH ;
Price, CJ ;
Wilson, J ;
Moss, HE ;
Matthews, PM ;
Tyler, LK .
NEUROIMAGE, 2000, 11 (06) :589-600
[10]   DIRECT FLASH MR IMAGING OF MAGNETIC-FIELD INHOMOGENEITIES BY GRADIENT COMPENSATION [J].
FRAHM, J ;
MERBOLDT, KD ;
HANICKE, W .
MAGNETIC RESONANCE IN MEDICINE, 1988, 6 (04) :474-480