摘要
Background: Several strategies to reduce construct stiffness have been proposed to promote secondary bone healing following fracture fixation with locked bridge plating constructs. However, stiffness reduction is typically gained at the cost of construct strength. In the present study, we tested whether a novel strategy for stiffness reduction, termed far cortical locking, can significantly reduce the stiffness of a locked plating construct while retaining its strength. Methods: Locked plating constructs and far cortical locking constructs were tested in a diaphyseal bridge plating model of the non-osteoporotic femoral diaphysis to determine construct stiffness in axial compression, torsion, and bending. Subsequently, constructs were dynamically loaded until failure in each loading mode to determine construct strength and failure modes. Finally, failure tests were repeated in a validated model of the osteoporotic femoral diaphysis to determine construct strength and failure modes in a worst-case scenario of bridge plating in osteoporotic bone. Results: Compared with the locked plating constructs, the initial stiffness of far cortical locking constructs was 88% lower in axial compression (p < 0.001), 58% lower in torsion (p < 0.001), and 29% lower in bending (p < 0.001). Compared with the locked plating constructs, the strength of far cortical locking constructs was 7% lower (p = 0.005) and 16% lower (p < 0.001) under axial compression in the non-osteoporotic and osteoporotic diaphysis, respectively. However, far cortical locking constructs were 54% stronger (p < 0.001) and 9% stronger (p = 0.04) under torsion and 21% stronger (p < 0.001) and 20% stronger (p = 0.02) under bending than locked plating constructs in the non-osteoporotic and osteoporotic diaphysis, respectively. Within the initial stiffness range, far cortical locking constructs generated nearly parallel interfragmentary motion. Locked plating constructs generated significantly less motion at the near cortex adjacent to the plate than at the far cortex (p < 0.01). Conclusions: Far cortical locking significantly reduces the axial stiffness of a locked plating construct. This gain in flexibility causes only a modest reduction in axial strength and increased torsional and bending strength. Clinical Relevance: Far cortical locking may provide a novel bridge plating strategy to enhance interfragmentary motion for the promotion of secondary bone healing while retaining sufficient construct strength.
引用
收藏
页码:1985 / 1994
页数:10
相关论文
共 52 条
[1]
Biomechanical testing of the locking compression plate: When does the distance between bone and implant significantly reduce construct stability? [J].
Ahmad, M. ;
Nanda, R. ;
Bajwa, A. S. ;
Candal-Couto, J. ;
Green, S. ;
Hui, A. C. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2007, 38 (03) :358-364
[2]
Shear movement at the fracture site delays healing in a diaphyseal fracture model [J].
Augat, P ;
Burger, J ;
Schorlemmer, S ;
Henke, T ;
Peraus, M ;
Claes, L .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2003, 21 (06) :1011-1017
[3]
Beaupre G S, 1992, J Orthop Trauma, V6, P294, DOI 10.1097/00005131-199209000-00005
[4]
Shear does not necessarifly inhibit bone healing [J].
Bishop, N. E. ;
van Rhijn, M. ;
Tami, I. ;
Corveleijn, R. ;
Schneider, E. ;
Ito, K. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (443) :307-314
[5]
Failure of less invasive stabilization system plates in the distal femur - A report of four cases [J].
Button, G ;
Wolinsky, P ;
Hak, D .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (08) :565-570
[6]
Comparison of the mechanical performance of three types of external fixators: Linear, circular and hybrid [J].
Caja, VL ;
Kim, W ;
Larsson, S ;
Chao, EYS .
CLINICAL BIOMECHANICS, 1995, 10 (08) :401-406
[7]
Fracture toughness and fatigue crack propagation rate of short fiber reinforced epoxy composites for analogue cortical bone [J].
Chong, Alexander C. M. ;
Miller, Forrest ;
Buxton, Mckee ;
Friis, Elizabeth A. .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2007, 129 (04) :487-493
[8]
EFFECT OF DYNAMIZATION ON GAP HEALING OF DIAPHYSEAL FRACTURES UNDER EXTERNAL FIXATION [J].
CLAES, LE ;
WILKE, HJ ;
AUGAT, P ;
RUBENACKER, S ;
MARGEVICIUS, KJ .
CLINICAL BIOMECHANICS, 1995, 10 (05) :227-234
[9]
Claes LE, 1998, CLIN ORTHOP RELAT R, pS132
[10]
Duda GN, 2002, CLIN ORTHOP RELAT R, P163