摘要
Ultrashort-echo-time (UTE) sequences have been proposed in the past for MR-based attenuation correction of PET data, because of their ability to image cortical bone. In the present work we assessed the limitations of dual-echo UTE imaging for bone segmentation in head and neck imaging. Sequentially acquired MR and PET/CT clinical data were used for this purpose. Methods: Twenty patients referred for a clinical oncology examination were scanned using a trimodality setup. Among the MR sequences, a dual-echo UTE acquisition of the head was acquired and used to create tissue R2 maps. The different undesired structures present in these maps were identified by an experienced radiologist. Global and local measurements of the overlap between R2-based and CT-based bone masks were computed. Results: UTE R2 maps displayed a nonfunctional relation with CT data. The obtained bone masks showed acceptable overlap with the corresponding CT data, in the case of the skull itself (e.g., 47% mis-match for the parietal region), with decreased performance in the base of the skull and in the neck (e.g., 78% for the maxillary region). Unwanted structures were detected, both anatomic (e.g., sternocleidomastoid, temporal, and masseter muscles) and artifactual (e.g., dental implants and air-tissue interfaces). Conclusion: It is indeed possible to estimate the anatomic location of bone tissue using UTE sequences. However, using pure parametric maps for attenuation correction may lead to bias close to certain anatomic structures and areas of high magnetic field inhomogeneity. More sophisticated approaches are necessary to compensate for these effects.
引用
收藏
页码:780 / 785
页数:6
相关论文
共 29 条
[1]   Quantitative Ultrashort Echo Time (UTE) MRI of Human Cortical Bone: Correlation With Porosity and Biomechanical Properties [J].
Bae, Won C. ;
Chen, Peter C. ;
Chung, Christine B. ;
Masuda, Koichi ;
D'Lima, Darryl ;
Du, Jiang .
JOURNAL OF BONE AND MINERAL RESEARCH, 2012, 27 (04) :848-857
[2]   MRI-Based Attenuation Correction for Hybrid PET/MRI Systems: A 4-Class Tissue Segmentation Technique Using a Combined Ultrashort-Echo-Time/Dixon MRI Sequence [J].
Berker, Yannick ;
Franke, Jochen ;
Salomon, Andre ;
Palmowski, Moritz ;
Donker, Henk C. W. ;
Temur, Yavuz ;
Mottaghy, Felix M. ;
Kuhl, Christiane ;
Izquierdo-Garcia, David ;
Fayad, Zahi A. ;
Kiessling, Fabian ;
Schulz, Volkmar .
JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (05) :796-804
[3]   MR-based attenuation correction for torso-PET/MR imaging:: pitfalls in mapping MR to CT data [J].
Beyer, Thomas ;
Weigert, Markus ;
Quick, Harald H. ;
Pietrzyk, Uwe ;
Vogt, Florian ;
Palm, Christoph ;
Antoch, Gerald ;
Mueller, Stefan P. ;
Bockisch, Andreas .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 (06) :1142-1146
[4]   MR-Based PET Attenuation Correction for PET/MR Imaging [J].
Bezrukov, Ilja ;
Mantlik, Frederic ;
Schmidt, Holger ;
Schoelkopf, Bernhard ;
Pichler, Bernd J. .
SEMINARS IN NUCLEAR MEDICINE, 2013, 43 (01) :45-59
[5]   Positron emission tomography (PET) attenuation correction artefacts in PET/CT and PET/MRI [J].
Buchbender, C. ;
Hartung-Knemeyer, V. ;
Forsting, M. ;
Antoch, G. ;
Heusner, T. A. .
BRITISH JOURNAL OF RADIOLOGY, 2013, 86 (1025)
[6]   MR imaging near metal with undersampled 3D radial UTE-MAVRIC sequences [J].
Carl, Michael ;
Koch, Kevin ;
Du, Jiang .
MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (01) :27-36
[7]   PET/MRI for Neurologic Applications [J].
Catana, Ciprian ;
Drzezga, Alexander ;
Heiss, Wolf-Dieter ;
Rosen, Bruce R. .
JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (12) :1916-1925
[8]   Toward Implementing an MRI-Based PET Attenuation-Correction Method for Neurologic Studies on the MR-PET Brain Prototype [J].
Catana, Ciprian ;
van der Kouwe, Andre ;
Benner, Thomas ;
Michel, Christian J. ;
Hamm, Michael ;
Fenchel, Matthias ;
Fischl, Bruce ;
Rosen, Bruce ;
Schmand, Matthias ;
Sorensen, A. Gregory .
JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (09) :1431-1438
[9]   Qualitative and quantitative ultrashort-TE MRI of cortical bone [J].
Du, Jiang ;
Bydder, Graeme M. .
NMR IN BIOMEDICINE, 2013, 26 (05) :489-506
[10]   Design and analysis of a practical 3D cones trajectory [J].
Gurney, PT ;
Hargreaves, BA ;
Nishimura, DG .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (03) :575-582