Correlation between tumor size and blood volume in lung tumors: a prospective study on dual-energy gemstone spectral CT imaging

被引:51
作者
Aoki, Masahiko [1 ]
Takai, Yoshihiro [1 ]
Narita, Yuichiro [1 ]
Hirose, Katsumi [1 ]
Sato, Mariko [1 ]
Akimoto, Hiroyoshi [1 ]
Kawaguchi, Hideo [1 ]
Hatayama, Yoshiomi [1 ]
Miura, Hiroyuki [1 ]
Ono, Shuichi [1 ]
机构
[1] Hirosaki Univ, Grad Sch Med, Dept Radiol & Radiat Oncol, Hirosaki, Aomori 0368562, Japan
基金
日本学术振兴会;
关键词
dual-energy CT; gemstone spectral imaging; lung tumor; iodine density; perfusion; HYPOXIA-INDUCIBLE FACTOR-1-ALPHA; STEREOTACTIC RADIOTHERAPY; INITIAL-EXPERIENCE; PERFUSION-CT; CANCER; ENHANCEMENT; EXPRESSION;
D O I
10.1093/jrr/rru026
中图分类号
Q [生物科学];
学科分类号
090105 [作物生产系统与生态工程];
摘要
The purpose of this study was to investigate the relationship between tumor size and blood volume for patients with lung tumors, using dual-energy computed tomography (DECT) and a gemstone spectral imaging (GSI) viewer. During the period from March 2011 to March 2013, 50 patients with 57 medically inoperable lung tumors underwent DECT before stereotactic body radiotherapy (SBRT) of 50-60 Gy in 5-6 fractions. DECT was taken for pretreatment evaluation. The region-of-interest for a given spatial placement of the tumors was set, and averages for CT value, water density and iodine density were compared with tumor size. The average values for iodine density in tumors of <= 2 cm, 2-3 cm, and >3 cm maximum diameter were 24.7, 19.6 and 16.0 (100 mu g/cm(3)), respectively. The average value of the iodine density was significantly lower in larger tumors. No significant correlation was detected between tumor size and average CT value or between tumor size and average water density. Both the average water density and the average CT value were affected by the amount of air in the tumor, but the average iodine density was not affected by air in the tumor. The average water density and the average CT value were significantly correlated, but the average iodine density and the average CT value showed no significant correlation. The blood volume of tumors can be indicated by the average iodine density more accurately than it can by the average CT value. The average iodine density as assessed by DECT might be a non-invasive and quantitative assessment of the radio-resistance ascribable to the hypoxic cell population in a tumor.
引用
收藏
页码:917 / 923
页数:7
相关论文
共 22 条
[1]
Dual-Energy CT: Oncologic Applications [J].
De Cecco, Carlo Nicola ;
Darnell, Anna ;
Rengo, Marco ;
Muscogiuri, Giuseppe ;
Bellini, Davide ;
Ayuso, Carmen ;
Laghi, Andrea .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) :S98-S105
[2]
Size matters: A comparison of T1 and T2 peripheral non-small-cell lung cancers treated with stereotactic body radiation therapy (SBRT) [J].
Dunlap, Neal E. ;
Larner, James M. ;
Read, Paul W. ;
Kozower, Benjamin D. ;
Lau, Christine L. ;
Sheng, Ke ;
Jones, David R. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 140 (03) :583-589
[3]
A challenge to traditional radiation oncology [J].
Fowler, JF ;
Tomé, WA ;
Fenwick, JD ;
Mehta, MP .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (04) :1241-1256
[4]
Dual-energy CT revisited with multidetector CT: review of principles and clinical applications [J].
Karcaaltincaba, Musturay ;
Aktas, Aykut .
DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2011, 17 (03) :181-194
[5]
Can Dual-energy CT Evaluate Contrast Enhancement of Ground-glass Attenuation? Phantom and Preliminary Clinical Studies [J].
Kawai, Tatsuya ;
Shibamoto, Yuta ;
Hara, Masaki ;
Arakawa, Toshinao ;
Nagai, Keiichi ;
Ohashi, Kazuya .
ACADEMIC RADIOLOGY, 2011, 18 (06) :682-689
[6]
Clinicopathological significance of hypoxia-inducible factor-1α expression in human pancreatic carcinoma [J].
Kitada, T ;
Seki, S ;
Sakaguchi, H ;
Sawada, T ;
Hirakawa, K ;
Wakasa, K .
HISTOPATHOLOGY, 2003, 43 (06) :550-555
[7]
Dual-energy perfusion-CT of pancreatic adenocarcinoma [J].
Klauss, M. ;
Stiller, W. ;
Pahn, G. ;
Fritz, F. ;
Kieser, M. ;
Werner, J. ;
Kauczor, H. U. ;
Grenacher, L. .
EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (02) :208-214
[8]
Dual energy computed tomography of lung nodules: Differentiation of iodine and calcium in artificial pulmonary nodules in vitro [J].
Knoess, Naomi ;
Hoffmann, Beata ;
Krauss, Bernhard ;
Heller, Martin ;
Biederer, Juergen .
EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (03) :E516-E519
[9]
A phase II study on stereotactic body radiotherapy for stage I non-small cell lung cancer [J].
Koto, Masashi ;
Takai, Yoshihiro ;
Ogawa, Yoshihiro ;
Matsushita, Haruo ;
Takeda, Ken ;
Takahashi, Chiaki ;
Britton, Keith R. ;
Jingu, Kei-ichi ;
Takai, Kenji ;
Mitsuya, Masatoshi ;
Nemoto, Kenji ;
Yamada, Shogo .
RADIOTHERAPY AND ONCOLOGY, 2007, 85 (03) :429-434
[10]
Outcomes of Stereotactic Ablative Radiotherapy in Patients With Potentially Operable Stage I Non-Small Cell Lung Cancer [J].
Lagerwaard, Frank J. ;
Verstegen, Naomi E. ;
Haasbeek, Cornelis J. A. ;
Slotman, Ben J. ;
Paul, Marinus A. ;
Smit, Egbert F. ;
Senan, Suresh .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (01) :348-353