TACT imaging of primary caries

被引:38
作者
Tyndall, DA [1 ]
Clifton, TL [1 ]
Webber, RL [1 ]
Ludlow, JB [1 ]
Horton, RA [1 ]
机构
[1] WAKE FOREST UNIV, BOWMAN GRAY SCH MED, DEPT DENT & RADIOL, WINSTON SALEM, NC USA
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY | 1997年 / 84卷 / 02期
关键词
D O I
10.1016/S1079-2104(97)90072-X
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. Tuned-aperture computed tomography, a new method for creating 3-D radiographic information based on optical aperture theory, was evaluated for diagnostic efficacy in primary caries detection. Study design, Sixty-four extracted teeth with 89 carious lesions were imaged with D-speed film, direct digital, And TACT modalities. A commercially available, 8-bit, charge-coupled device was used in the later two modalities. Six trained observers were asked to identify the presence or absence and depth oi interproximal and occlusal lesions for all three modalities. The teeth were sectioned and examined microscopically to determine ground truth. Logistic regression analysis was performed for all three imaging systems for the detection task. Analysis of variance was used for depth determination. Detection of lesion, depth of lesion accuracy, and time for diagnosis were also examined. Results, For caries detection TACT and film were not different (p = 0.2216) with the Wald statistic, Film and TACT were significantly more accurate than the digital system (p = 0.0001). Scheffe's post hoc test revealed that TACT and film were more accurate than the direct digital system for determining lesion depth (p = 0.05) but not statistically different when compared with each other. The detection data were substantiated further by receiver operating characteristic analysis that demonstrated similar statistical relationships. Time required per diagnosis was not shown to be statistically different among the three imaging modalities. Conclusions, We conclude for caries detection and depth determination that TACT could not be distinguished from film despite the significant relative loss of information capacity in the charge-coupled device receptor. The relatively poorer performance yielded by the digital control images suggests that increased information capacity associated with more modern charge-coupled device detectors may improve diagnostic performance for both direct digital and TACT displays over that demonstrated in this investigation.
引用
收藏
页码:214 / 225
页数:12
相关论文
共 26 条
[1]  
Bader J D, 1993, J Dent Educ, V57, P415
[2]   STUDY TO DEVELOP A RATING SYSTEM AND EVALUATE DENTAL RADIOGRAPHS SUBMITTED TO A 3RD PARTY CARRIER [J].
BEIDEMAN, RW ;
JOHNSON, ON ;
ALCOX, RW .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1976, 93 (05) :1010-1013
[3]  
CLARK D E, 1990, Journal of Oral Implantology, V16, P156
[4]  
des Plantes BGZ, 1932, ACTA RADIOL, V13, P182
[5]   CLINICAL EFFICACY OF DENTAL RADIOGRAPHY IN THE DETECTION OF DENTAL-CARIES AND PERIODONTAL-DISEASES [J].
DOUGLASS, CW ;
VALACHOVIC, RW ;
WIJESINHA, A ;
CHAUNCEY, HH ;
KAPUR, KK ;
MCNEIL, BJ .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1986, 62 (03) :330-339
[6]  
Dove S B, 1992, Dentomaxillofac Radiol, V21, P127
[7]   AN EXPERIMENTAL-STUDY OF NEW DIAGNOSTIC METHODS FOR THE EXAMINATION OF OSSEOUS LESIONS IN THE TEMPOROMANDIBULAR-JOINT [J].
ENGELKE, W ;
RUTTIMANN, UE ;
TSUCHIMOCHI, M ;
BACHER, JD .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1992, 73 (03) :348-359
[8]   RADIOGRAPHIC DIAGNOSES AND TREATMENT DECISIONS ON APPROXIMAL CARIES [J].
ESPELID, I .
COMMUNITY DENTISTRY AND ORAL EPIDEMIOLOGY, 1986, 14 (05) :265-270
[10]   COMPUTERIZED TOMOSYNTHESIS OF DENTAL-TISSUES [J].
GROENHUIS, RAJ ;
WEBBER, RL ;
RUTTIMANN, UE .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1983, 56 (02) :206-214