Determination of entrained fraction in vertical annular gas/liquid flow

被引:28
作者
Azzopardi, BJ [1 ]
Zaidi, SH
机构
[1] Univ Nottingham, Sch Chem Environm & Min Engn, Nottingham NG7 2RD, England
[2] Princeton Univ, Dept Mech & Aerosp Engn, Princeton, NJ 08544 USA
来源
JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME | 2000年 / 122卷 / 01期
关键词
D O I
10.1115/1.483236
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
A new technique for the measurement of drop concentration in annular gas/liquid is presented This is based on scattering of light by the drops. From the measured concentration, entrained liquid flow rate and thence the entrained fraction can be determined. The technique has been employed to obtain new data for vertical upward annular flow in a 0.038 in diameter pipe. The results have been compared with data from different pipe diameters and with the predictions of an annular flow model. [S0048-2202(00)02201-X].