A count rate model for PET and its application to an LSO HR PLUS scanner

被引:21
作者
Moisan, C
Rogers, JG
Douglas, JL
机构
[1] TRIUMF, 4004 Wesbrook Mall, Vancouver
关键词
D O I
10.1109/23.596991
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present a count rate model for PET. Considering a standard 20x20 cm phantom in the field-of-view of a cylindrical septaless tomograph, the model computes the acceptance to prompt and random events from simple geometric considerations. Dead time factors at all stages of a typical event acquisition architecture are calculated from specified processing clock cycles. Validations of the model's predictions against the measured performances of the ECAT-953B and the EXACT HR PLUS are presented. The model is then used to investigate the benefit of using detectors made of LSO in the EXACT HR PLUS scanner geometry. The results indicate that in replacing BGO by the faster LSO, one can count on an increase of the peak noise-equivalent-count rate by a factor 2.2. This gain will be achieved by using a 5 nsec coincidence window, buckets operating on a 128 nsec clock cycle, and a front-end data acquisition that can sustain a total event rate of 2.9 MHz.
引用
收藏
页码:1219 / 1224
页数:6
相关论文
共 9 条
[1]  
Casey M, GSFC Internal Private Communication
[2]  
CASEY ME, 1992, THESIS U TENNESSEE K
[3]   A SIMPLE DATA LOSS MODEL FOR POSITRON CAMERA SYSTEMS [J].
ERIKSSON, L ;
WIENHARD, K ;
DAHLBOM, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) :1566-1570
[4]  
KARP JS, 1991, J NUCL MED, V32, P2342
[5]   ADVANTAGES AND LIMITATIONS OF LSO SCINTILLATOR IN NUCLEAR-PHYSICS EXPERIMENTS [J].
LUDZIEJEWSKI, T ;
MOSZYNSKA, K ;
MOSZYNSKI, M ;
WOLSKI, D ;
KLAMRA, W ;
NORLIN, LO ;
DEVITSIN, E ;
KOZLOV, V .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) :328-336
[6]   A Monte Carlo study of the acceptance to scattered events in a depth encoding PET camera [J].
Moisan, C ;
Tupper, P ;
Rogers, JG ;
deJong, JK .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) :1974-1980
[7]   PHYSICAL PERFORMANCE OF A POSITRON TOMOGRAPH FOR BRAIN IMAGING WITH RETRACTABLE SEPTA [J].
SPINKS, TJ ;
JONES, T ;
BAILEY, DL ;
TOWNSEND, DW ;
GROOTOONK, S ;
BLOOMFIELD, PM ;
GILARDI, MC ;
CASEY, ME ;
SIPE, B ;
REED, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (08) :1637-1655
[8]   ANALYTICAL STUDY OF THE PERFORMANCE OF A MULTILAYER POSITRON COMPUTED-TOMOGRAPHY SCANNER [J].
TANAKA, E ;
NOHARA, N ;
TOMITANI, T ;
ENDO, M .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1982, 6 (02) :350-364
[9]  
YOUNG JW, 1993, NUCLEAR SCIENCE SYMPOSIUM & MEDICAL IMAGING CONFERENCE, VOLS 1-3, P1205, DOI 10.1109/NSSMIC.1993.701835