Improved precision measurement of the Casimir force

被引:212
作者
Roy, A [1 ]
Lin, CY [1 ]
Mohideen, U [1 ]
机构
[1] Univ Calif Riverside, Dept Phys, Riverside, CA 92521 USA
来源
PHYSICAL REVIEW D | 1999年 / 60卷 / 11期
关键词
D O I
10.1103/PhysRevD.60.111101
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
We report an improved precision measurement of the Casimir force. The force is measured between a large Al coated sphere and flat plate using an;atomic force microscope. primary experimental improvements include the use of smoother metal coatings, reduced noise, lower systematic errors, and independent measurement of surface separations. Also the complete dielectric spectrum of the metal is used in the theory. The average statistical precision remains at the same 1% of the forces: measured at the closest separation. [S0556-2821(99)50421-9].