Integration of a microextraction system on a glass chip:: Ion-pair solvent extraction of Fe(II) with 4,7-diphenyl-1,10-phenanthrolinedisulfonic acid and tri-n-octylmethylammonium chloride

被引:235
作者
Tokeshi, M
Minagawa, T
Kitamori, T
机构
[1] Kanagawa Acad Sci & Technol, Integrated Chem Project, Takatsu Ku, Kawasaki, Kanagawa 2130012, Japan
[2] Univ Tokyo, Grad Sch Engn, Dept Appl Chem, Bunkyo Ku, Tokyo 1138656, Japan
关键词
D O I
10.1021/ac991147f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An ion-pair solvent extraction was performed in a microchannel fabricated in a quartz glass chip. The aqueous solution of Fe-bathophenanthrolinedisulfonic acid complex and the chloroform solution of tri-n-octylmethyl-ammonium chloride were introduced into the microchannel, and a parallel two-phase laminar now was formed. The ion-pair product extracted in chloroform was monitored by the thermal lens microscope. The ion-pair product was gradually extracted from aqueous solution into chloroform when the flow was very slow or stopped, while nothing was extracted into chloroform when the flow was fast. The time for extraction in the present 250 mu m microchannel, 45 s, roughly coincided with the molecular diffusion time, and the extraction time was at least 1 order shorter compared with the ordinary extraction time using a separatory funnel and mechanical shaking. The micro-space in the microchannel was characterized by the large specific interface area and short diffusion distance, and these characteristics may contribute to highly efficient extraction without mechanical shaking. The success of this molecular transport may lead to the integration of more complicated separation and chemical operations on a microchip and more applications.
引用
收藏
页码:1711 / 1714
页数:4
相关论文
共 20 条
[1]  
Bialkowski S., 2019, Photothermal spectroscopy methods
[2]   Diffusion-based extraction in a microfabricated device [J].
Brody, JP ;
Yager, P .
SENSORS AND ACTUATORS A-PHYSICAL, 1997, 58 (01) :13-18
[3]  
Freemantle M, 1999, CHEM ENG NEWS, V77, P27, DOI 10.1021/cen-v077n044.p027
[4]   Powerful tools for genetic analysis come of age [J].
Graves, DJ .
TRENDS IN BIOTECHNOLOGY, 1999, 17 (03) :127-134
[5]   USES OF LIQUID ION-EXCHANGERS IN INORGANIC ANALYSIS [J].
GREEN, H .
TALANTA, 1973, 20 (02) :139-161
[6]  
HARRISON DJ, 1998, MICRO TOTAL ANAL SYS
[7]   APPLICATION OF THE THERMAL LENS EFFECT FOR DETERMINATION OF IRON(II) WITH 4,7-DIPHENYL-1,10-PHENANTHROLINE DISULFONIC ACID [J].
IMASAKA, T ;
MIYAISHI, K ;
ISHIBASHI, N .
ANALYTICA CHIMICA ACTA, 1980, 115 (MAR) :407-410
[8]   Quantitative analysis of molecular interaction in a microfluidic channel: The T-sensor [J].
Kamholz, AE ;
Weigl, BH ;
Finlayson, BA ;
Yager, P .
ANALYTICAL CHEMISTRY, 1999, 71 (23) :5340-5347
[9]   Microfabrication inside capillaries using multiphase laminar flow patterning [J].
Kenis, PJA ;
Ismagilov, RF ;
Whitesides, GM .
SCIENCE, 1999, 285 (5424) :83-85
[10]  
KITAMORI T, 1991, SPECTROCHIM ACTA REV, V14, P275