Determination of atomic isotope patterns from mass spectra of molecular ions containing multiple polyisotopic elements

被引:4
作者
Brito-Neto, JGA [1 ]
do Lago, CL [1 ]
机构
[1] Univ Sao Paulo, Inst Quim, BR-05508900 Sao Paulo, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
isotopic ratio; isotope pattern; chemometrics; deconvolution; electrospray;
D O I
10.1016/S1387-3806(02)00555-9
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
A chemometrical method that allows one to obtain the isotopic abundances of the atoms composing a molecular ion, given its elemental composition and its mass spectrum, was developed. The method uses non-linear regression to fit the isotopic abundances of the elements, so that the experimental spectrum of the ion is reproduced. A least squares method with minimization by downhill simplex algorithm was implemented in C language as a library, but a graphical user interface application that allows an end-user to apply the method to his/her own spectra is also available. Examples of its application to electrospray mass spectra of NaAuCl4 and CdCl2 are given. The chlorine isotope pattern was obtained from the AuCl4- cluster in the former case and, simultaneously, chlorine and cadmium isotope patterns from the CdCl3- cluster. The performance of the method was extensively characterized by applying it to a great number of simulated spectra. Non-idealities, against which the method was evaluated, include noise, mass discrimination, detection non-linearity, base line offset (background counting), and low resolution. It has been demonstrated that, in spite of what intuition might tell one, the polyatomic approach to isotopic analyses has no a priori disadvantage to the common monatomic approach, Indeed, the results demonstrate that, in some cases, the figures of merit can be improved by using polyatomic species and that other polyisotopic elements can be included in the formula without significant loss of precision, as long as they have a dominant isotope, which is the case of carbon, hydrogen, oxygen, and nitrogen, for example. This means that polyatomic species derived from organic species could be useful for isotopic measurement purposes. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:95 / 113
页数:19
相关论文
共 22 条
[1]  
Bacon JR, 1997, J ANAL ATOM SPECTROM, V12, pR407
[2]  
Brand WA, 1996, J MASS SPECTROM, V31, P225, DOI 10.1002/(SICI)1096-9888(199603)31:3<225::AID-JMS319>3.0.CO
[3]  
2-L
[4]  
Datta BP, 2000, RAPID COMMUN MASS SP, V14, P1571, DOI 10.1002/1097-0231(20000915)14:17<1571::AID-RCM60>3.0.CO
[5]  
2-Y
[6]   ISOTOPIC ANALYSIS OF A LI-6 ENRICHED LITHIUM SAMPLE EMPLOYING THE LI2BO2+ ION-BEAM METHOD - VERIFICATION OF THE THEORETICAL ACCURACY [J].
DATTA, BP ;
PARAB, AR ;
KHODADE, PS ;
CHITAMBAR, SA ;
JAIN, HC .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1995, 142 (1-2) :69-81
[7]  
Datta BP, 2000, RAPID COMMUN MASS SP, V14, P706, DOI 10.1002/(SICI)1097-0231(20000430)14:8<706::AID-RCM929>3.0.CO
[8]  
2-#
[9]   MOLECULAR ION-BEAM METHOD OF ISOTOPIC ANALYSIS - EFFECT OF ERROR PROPAGATION, A CASE-STUDY WITH LI2BO2+ [J].
DATTA, BP ;
KHODADE, PS ;
PARAB, AR ;
GOYAL, AH ;
CHITAMBAR, SA ;
JAIN, HC .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (07) :581-586
[10]   THERMAL IONIZATION MASS-SPECTROMETRY OF LI2BO2+ IONS - DETERMINATION OF THE ISOTOPIC ABUNDANCE RATIO OF LITHIUM [J].
DATTA, BP ;
KHODADE, PS ;
PARAB, AR ;
GOYAL, AH ;
CHITAMBAR, SA ;
JAIN, HC .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1992, 116 (02) :87-114