Spectrofluorometric determination of naproxen in tablets

被引:57
作者
Damiani, P [1 ]
Bearzotti, M [1 ]
Cabezón, MA [1 ]
机构
[1] Univ Nacl Rosario, Fac Ciencias Bioquim & Farmaceut, Dept Quim Analit, RA-2000 Rosario, Santa Fe, Argentina
关键词
spectrofluorometry; naproxen; HPLC; bivariate least square regression;
D O I
10.1016/S0731-7085(02)00063-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid, selective, sensitive and simple fluorescence method was developed for the direct determination of naproxen in tablets. The tablets were triturated, dissolved in either NH3 or NaOH solution, sonicated, filtered and then direct fluorescence emission was read at 353 nm (exciting at 271 nm). In order to validate the method the results were compared with those obtained by the USP XXIV NF 19 Pharmacopeia, reference method (high performance liquid chromatography). The slope, intercept and variances which are associated with the regression coefficient calculated with bivariate least square (BLS) regression indicate that both methods are statistically comparable. The recoveries were excellent, except in tablets containing the antibiotic tetracycline. In this latter case a correction procedure is necessary. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:229 / 238
页数:10
相关论文
共 57 条
[1]   Determination of naproxen in liver and kidney tissues by electrokinetic capillary chromatography with laser-induced fluorescence detection [J].
Albrecht, C ;
Thormann, W .
JOURNAL OF CHROMATOGRAPHY A, 1998, 802 (01) :115-120
[2]  
Albrecht C, 1997, CLIN CHEM, V43, P2083
[3]  
ALRASHOOD KA, 1994, SCI PHARM, V62, P215
[4]  
ANDERSEN JV, 1992, J CHROMATOGR-BIOMED, V577, P325
[5]  
Baeyens WRG, 1999, BIOMED CHROMATOGR, V13, P450, DOI 10.1002/(SICI)1099-0801(199911)13:7<450::AID-BMC910>3.0.CO
[6]  
2-1
[7]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF NAPROXEN, IBUPROFEN AND DICLOFENAC IN PLASMA AND SYNOVIAL-FLUID IN MAN [J].
BLAGBROUGH, IS ;
DAYKIN, MM ;
DOHERTY, M ;
PATTRICK, M ;
SHAW, PN .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 578 (02) :251-257
[8]   STRAIGHT-LINE CALIBRATION - SOMETHING MORE THAN SLOPES, INTERCEPTS, AND CORRELATION-COEFFICIENTS [J].
BOQUE, R ;
RIUS, FX ;
MASSART, DL .
JOURNAL OF CHEMICAL EDUCATION, 1994, 71 (03) :230-232
[9]   Determination of naproxen with chemiluminescence detection [J].
Campiglio, A .
ANALYST, 1998, 123 (07) :1571-1574
[10]   DETECTION LIMITS WITH SPECIFIED ASSURANCE PROBABILITIES [J].
CLAYTON, CA ;
HINES, JW ;
ELKINS, PD .
ANALYTICAL CHEMISTRY, 1987, 59 (20) :2506-2514