Rotational digital subtraction angiography of carotid artery bifurcation stenoses.

被引:2
作者
Biederer, J [1 ]
Link, J [1 ]
Peter, D [1 ]
Kopp, U [1 ]
Heller, M [1 ]
机构
[1] Univ Kiel, Klin Diagnost Radiol, D-24105 Kiel, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 1999年 / 171卷 / 04期
关键词
carotid artery; stenosis; rotational angiography; DSA;
D O I
10.1055/s-1999-11093
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Purpose: A prospective study was designed to evaluate, whether multiplanar imaging with rotational digital subtraction angiography (R-DSA) could improve assessment of carotid artery bifurcation stenosis. Patients and methods: 45 patients with suspected stenosis of the ICA were examined with DSA in standard projections (0 degrees-(45 degrees)-90 degrees) and additional R-DSA of each ICA from 0-90 degrees in 10 degrees steps. We compared imaging quality and degree of stenosis as well as exposure of the patients to radiation and contrast media. Results: 79/82 R-DSA (96 %) were suitable for evaluation of stenosis, 58/82 (70%) matched the quality standard of single projection DSA. Specificity and sensitivity of the R-DSA to diagnose high grade ACI stenosis were 100% and 94%, respectively. 7/79 R-DSA revealed a higher and 3/79 a lower degree of stenosis than the corresponding DSA. Regarding the degree of stenosis there was no significant difference between the two modalities (p > 0,05), but R-DSA detected 4 stenoses greater than 60% that were estimated to be lower than 60% by DSA. Radiation dose for R-DSA was equivalent to one DSA run (170 cGycm(2)). The average amount of contrast media (25 ml) was slightly higher than for 2-3 single-projection DSA (19,8 ml). Conclusions: R-DSA provides high quality imaging of the carotid bifurcation with multiplanar projections facilfitating exact grading of vessel stenosis. The number of cases (n = 2) is to small to judge the value of R-DSA as to (tandem-) stenosis of the distal ICA. Still, diagnostic value and low radiation exposure justify the use of R-DSA as additional series to standard protocols.
引用
收藏
页码:283 / 289
页数:7
相关论文
共 23 条
[1]
Carotid stenting and angioplasty: A statement for healthcare professionals from the councils on cardiovascular radiology, stroke, cardiovascular surgery, epidemiology and prevention, and clinical cardiology, American Heart Association [J].
Bettmann, MA ;
Katzen, BT ;
Whisnant, J ;
Brant-Zawadzki, M ;
Broderick, JP ;
Furlan, AJ ;
Hershey, LA ;
Howard, V ;
Kuntz, R ;
Loftus, CM ;
Pearce, W ;
Roberts, A ;
Roubin, G .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1998, 9 (01) :3-5
[2]
CORNELIS G, 1972, Acta Radiologica Diagnosis, V13, P74
[3]
HOFF DJ, 1994, AM J NEURORADIOL, V15, P1945
[4]
ROTATIONAL ANGIOGRAPHY OF RENAL-ARTERIES [J].
KLEIN, HM ;
VORWERK, D ;
NEUERBURG, J ;
GUNTHER, RW .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1995, 162 (03) :249-251
[5]
FIRST RESULTS OF SPIRAL CT ANGIOGRAPHY IN THE EVALUATION OF CAROTID-ARTERY STENOSIS [J].
LINK, J ;
MULLERHULSBECK, S ;
BROSSMANN, J ;
GRABENER, M ;
VOSS, C ;
HELLER, M .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1995, 162 (03) :204-208
[6]
MR angiography of the carotid arteries in 3D TOF-technique with sagittal ''double-slab'' acquisition using a new head-neck coil [J].
Link, J ;
Brinkmann, G ;
Steffens, JC ;
Graessner, J ;
MullerHulsbeck, S ;
Heller, M .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1996, 165 (06) :544-550
[7]
The value of 3D-CT angiography and duplex sonography in comparison to arteriography in carotid artery stenoses. [J].
Link, J ;
MullerHulsbeck, S ;
Wesner, F ;
Hopfner, M ;
Schwarzenberg, H ;
Heller, M .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1997, 166 (01) :30-35
[8]
MISSLER U, 1994, KONTRASTE
[9]
GUIDELINES FOR CAROTID ENDARTERECTOMY - A MULTIDISCIPLINARY CONSENSUS STATEMENT FROM THE AD-HOC-COMMITTEE, AMERICAN-HEART-ASSOCIATION [J].
MOORE, WS ;
BARNETT, HJM ;
BEEBE, HG ;
BERNSTEIN, EF ;
BRENER, BJ ;
BROTT, T ;
CAPLAN, LR ;
DAY, A ;
GOLDSTONE, J ;
HOBSON, RW ;
KEMPCZINSKI, RF ;
MATCHAR, DB ;
MAYBERG, MR ;
NICOLAIDES, AN ;
NORRIS, JW ;
RICOTTA, JJ ;
ROBERTSON, JT ;
RUTHERFORD, RB ;
THOMAS, D ;
TOOLE, JF ;
TROUT, HH ;
WIEBERS, DO .
CIRCULATION, 1995, 91 (02) :566-579
[10]
PROLONGED INJECTION ANGIOGRAPHY FOR DIAGNOSING INTRA-CRANICAL NEOPLASMS [J].
NUMAGUCHI, Y ;
KISHIKAWA, T ;
IKEDA, J ;
TSUKAMOTO, Y ;
FUKUI, M ;
KITAMURA, K ;
MATSUURA, K .
RADIOLOGY, 1980, 136 (02) :387-393