Interobserver and Intraobserver Reliability in the Evaluation of Mechanical Axis Deviation

被引:47
作者
Gordon, J. Eric [1 ,2 ,3 ]
Chen, Ryan C. [3 ]
Dobbs, Matthew B. [1 ,2 ,3 ]
Luhmann, Scott J. [1 ,2 ,3 ]
Rich, Margaret M. [2 ]
Schoenecker, Perry L. [1 ,2 ,3 ]
机构
[1] St Louis Childrens Hosp, St Louis, MO 63110 USA
[2] St Louis Shriners Hosp, St Louis, MO USA
[3] Washington Univ, Sch Med, Dept Orthopaed Surg, St Louis, MO 63130 USA
关键词
interobserver; intraobserver; reliability; measurement; mechanical axis; valgus; varus; VARUS-VALGUS ALIGNMENT; ONSET TIBIA VARA; PATELLOFEMORAL OSTEOARTHRITIS; LOWER-LIMBS; DEFORMITIES; FEMUR;
D O I
10.1097/BPO.0b013e31819b9188
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Background: The lateral distal femoral angle (LDFA), the medial proximal tibial angle (MPTA), and the mechanical axis deviation (MAD) are commonly used in the evaluation of lower extremity deformities. The interobserver and intraobserver reliabilities of these measurements have not been evaluated. Methods: Three groups of observers with different levels of experience (5 attending pediatric orthopaedic Surgeons, 5 orthopaedic chief residents, and 5 interns) measured the LDFA, MPTA, and MAD on 35 full-length standing anteroposterior teleroentgenograms (56 extremities). Relatively equal numbers of extremities with vat-Lis, valgus, and normal alignments were chosen to represent a spectrum of lower extremities that might be encountered clinically. Measurements were performed in random order by each observer on 2 separate occasions separated by at least 2 weeks. Results: The interobserver and intraobserver reliabilities for each of the measurements regardless of the level of experience was greater than or equal to 0.90. The interobserver differences were slightly greater than the intraobserver differences for all measurements. The overall mean interobserver differences for angular and MAD measurements were within 1.6 degrees and 3.1 mm, respectively. The overall mean intraobserver differences for angular and MAD measurements were within 1.4 degrees and 1.9 mm, respectively. Reliability and mean differences were consistent regardless of the level of experience. Conclusions: Measurement of the LDFA, MPTA, and MAD demonstrated excellent intraobserver and interobserver reliabilities regardless of the experience of the observer.
引用
收藏
页码:281 / 284
页数:4
相关论文
共 21 条
[1]
[Anonymous], 2000, FDN CLIN RES
[2]
Varus-valgus alignment in the progression of patellofemoral osteoarthritis [J].
Cahue, S ;
Dunlop, D ;
Hayes, K ;
Song, J ;
Torres, L ;
Sharma, L .
ARTHRITIS AND RHEUMATISM, 2004, 50 (07) :2184-2190
[3]
MEASUREMENT OF SCOLIOSIS AND KYPHOSIS RADIOGRAPHS - INTRAOBSERVER AND INTEROBSERVER VARIATION [J].
CARMAN, DL ;
BROWNE, RH ;
BIRCH, JG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (03) :328-333
[4]
Elahi S, 2000, ARTHRITIS RHEUM, V43, P1874, DOI 10.1002/1529-0131(200008)43:8<1874::AID-ANR25>3.0.CO
[5]
2-2
[6]
Femoral deformity in tibia vara [J].
Gordon, JE ;
King, DJ ;
Luhmann, SJ ;
Dobbs, MB ;
Schoenecker, PL .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (02) :380-386
[7]
Comprehensive treatment of late-onset tibia vara [J].
Gordon, JE ;
Heidenreich, FP ;
Carpenter, CJ ;
Kelly-Hahn, J ;
Schoenecker, PL .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (07) :1561-1570
[8]
GREENE WB, 1994, AAOS INSTR COURS LEC, V43, P151
[9]
Bone realignment with use of temporary external fixation for distal femoral valgus and varus deformities [J].
Gugenheim, JJ ;
Brinker, MR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (07) :1229-1237
[10]
PALEY D, 1992, CLIN ORTHOP RELAT R, P48