The sensitivity of tibiofemoral contact pressure to the size and shape of the lateral and medial menisci

被引:73
作者
Donahue, TLH
Hull, ML
Rashid, MM
Jacobs, CR
机构
[1] Michigan Technol Univ, Dept Mech Engn, Houghton, MI 49931 USA
[2] Univ Calif Davis, Dept Mech Engn, Davis, CA 95616 USA
[3] Univ Calif Davis, Dept Civil Engn, Davis, CA 95616 USA
[4] Stanford Univ, Dept Mech Engn, Stanford, CA 94305 USA
关键词
knee; geometry; allograft; meniscus;
D O I
10.1016/j.orthres.2003.12.010
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In an effort to prevent degeneration of articular cartilage associated with meniscectomies, both meniscal allografts and synthetic replacements have been studied. A number of biomechanical criteria may be important for a meniscal replacement to restore normal tibiofemoral contact pressure in the knee joint and hence be clinically successful. One of these criteria is geometric similarity. The objectives of the current study were to: determine the sensitivity of the contact variables of the tibia] plateau to the transverse depth and width of both the lateral and medial menisci; determine the sensitivity of the contact variables of the tibial plateau to the cross-sectional width and height of the lateral and medial menisci; and determine the tolerances on each of the four parameters for both menisci. To satisfy these objectives, a previously developed finite element model of the tibiofemoral joint was used to compute the contact pressure distribution on the tibial plateau. The effect of the above-mentioned geometric parameters on the contact behavior was studied by perturbing the finite element model. Results showed that the contact variables are similarly sensitive to both the transverse and cross-sectional parameters of the menisci. Additionally the medial meniscal parameters have a greater effect on the contact variables than do the lateral meniscal parameters. Finally, less than a 0.5 mm change in the medial meniscal height and greater than a I mm change in the lateral meniscal height could be tolerated before the relative difference in the contact variables from those for the original geometry exceeded 10%. Thus in the design or selection of meniscal replacements, each of the four parameters should be measured when sizing a replacement tissue. Also tighter tolerances should be placed on the medial meniscal parameters compared to the lateral meniscal parameters. (C) 2004 Orthopaedic Research Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:807 / 814
页数:8
相关论文
共 33 条
[1]
How three methods for fixing a medial meniscal autograft affect tibial contact mechanics [J].
Alhalki, MM ;
Howell, SM ;
Hull, ML .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1999, 27 (03) :320-328
[2]
LATE DEGENERATIVE CHANGES AFTER MENISCECTOMY - FACTORS AFFECTING THE KNEE AFTER OPERATION [J].
ALLEN, PR ;
DENHAM, RA ;
SWAN, AV .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1984, 66 (05) :666-671
[3]
[Anonymous], OSTEOARTHRITIS DIAGN
[4]
A new load application system for in vitro study of ligamentous injuries to the human knee joint [J].
Bach, JM ;
Hull, ML .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1995, 117 (04) :373-382
[5]
MENISCAL TEARS - THE EFFECT OF MENISCECTOMY AND OF REPAIR ON INTRAARTICULAR CONTACT AREAS AND STRESS IN THE HUMAN KNEE - A PRELIMINARY-REPORT [J].
BARATZ, ME ;
FU, FH ;
MENGATO, R .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1986, 14 (04) :270-275
[6]
LIGAMENT-BONE INTERACTION IN A 3-DIMENSIONAL MODEL OF THE KNEE [J].
BLANKEVOORT, L ;
HUISKES, R .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1991, 113 (03) :263-269
[7]
ISOLATED ARTHROSCOPIC PARTIAL MENISCECTOMY - FUNCTIONAL RADIOGRAPHIC EVALUATION AT 5 YEARS [J].
BOLANO, LE ;
GRANA, WA .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1993, 21 (03) :432-437
[8]
COX JS, 1975, CLIN ORTHOP RELAT R, P178
[9]
COX JS, 1977, CLIN ORTHOP RELAT R, P236
[10]
A finite element model of the human knee joint for the study of tibio-femoral contact [J].
Donahue, TLH ;
Hull, ML ;
Rashid, MM ;
Jacobs, CR .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2002, 124 (03) :273-280