Mediated amperometric glucose sensor modified by the sol-gel method

被引:43
作者
Li, J
Chia, LS
Goh, NK
Tan, SN
Ge, H
机构
[1] NANYANG TECHNOL UNIV,NATL INST EDUC,DIV CHEM,SINGAPORE 259756,SINGAPORE
[2] SINGAPORE PROD & STAND BOARD,SINGAPORE 118221,SINGAPORE
关键词
glucose sensors; ferrocene; amperometry; sol-gel process; OXIDASE; BIOSENSORS; ELECTRODE; GLASS; ENCAPSULATION;
D O I
10.1016/S0925-4005(97)80252-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An amperometric mediated glucose sensor has been developed via the sol-gel technique in a new 'sandwich' configuration: sol-gel-ferrocene:glucose oxidase (GOx):sol-gel using a carbon paste electrode as the primary electrode. The process parameters for the fabrication of a glucose sensor based on tetramethoxysilane (TMOS) sol-gel thin films utilizing ferrocene as a mediator have been optimized. In the sol-gel matrix, the results demonstrate that GOx still retains its activity, and ferrocene is efficient at shuttling the electrons between the enzyme redox centre and the electrode. Cyclic voltammetric and amperometric measurements have been used to study the response of the glucose sensor, which has a fast response and good reproducibility. The effect of oxygen on the sensor response has been investigated. The selectivity, lifetime and fabrication reproducibility of the sensor have also been evaluated. (C) 1997 Elsevier Science S.A.
引用
收藏
页码:135 / 141
页数:7
相关论文
共 21 条
[1]   ELECTROCHEMICAL PROBING OF THE ACTIVITY OF GLUCOSE-OXIDASE EMBEDDED SOL-GEL MATRICES [J].
AUDEBERT, P ;
DEMAILLE, C ;
SANCHEZ, C .
CHEMISTRY OF MATERIALS, 1993, 5 (07) :911-913
[2]  
Brinker C.J., 1989, Sol Gel Science
[3]   A REGENERABLE PSEUDO-REAGENTLESS GLUCOSE BIOSENSOR BASED ON NAFION POLYMER AND 1,1'-DIMETHYLFERRICINIUM MEDIATOR [J].
BROWN, RS ;
LUONG, JHT .
ANALYTICA CHIMICA ACTA, 1995, 310 (03) :419-427
[4]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[5]   SOL-GEL ENCAPSULATION METHODS FOR BIOSENSORS [J].
DAVE, BC ;
DUNN, B ;
VALENTINE, JS ;
ZINK, JI .
ANALYTICAL CHEMISTRY, 1994, 66 (22) :A1120-A1127
[6]   ENCAPSULATION OF PROTEINS IN TRANSPARENT POROUS SILICATE-GLASSES PREPARED BY THE SOL-GEL METHOD [J].
ELLERBY, LM ;
NISHIDA, CR ;
NISHIDA, F ;
YAMANAKA, SA ;
DUNN, B ;
VALENTINE, JS ;
ZINK, JI .
SCIENCE, 1992, 255 (5048) :1113-1115
[7]   SOL-GEL VANADIUM PENTAOXIDE GLUCOSE BIOSENSOR [J].
GLEZER, V ;
LEV, O .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1993, 115 (06) :2533-2534
[8]   ELECTRON MEDIATOR-MODIFIED ELECTRODE FOR THE DETERMINATION OF GLUCOSE IN FERMENTATION MEDIA [J].
GRUNDIG, B ;
KRABISCH, C .
ANALYTICA CHIMICA ACTA, 1989, 222 (01) :75-81
[9]   THE SOL-GEL PROCESS [J].
HENCH, LL ;
WEST, JK .
CHEMICAL REVIEWS, 1990, 90 (01) :33-72
[10]   RECENT ADVANCES IN AMPEROMETRIC GLUCOSE BIOSENSORS FOR IN-VIVO MONITORING [J].
JAFFARI, SA ;
TURNER, APF .
PHYSIOLOGICAL MEASUREMENT, 1995, 16 (01) :1-15