Comparison of outcome of unilateral locking plate and dual plating in the treatment of bicondylar tibial plateau fractures

被引:43
作者
Lee, Meng-Hsuan [1 ]
Hsu, Chien-Jen [1 ]
Lin, Kai-Cheng [1 ]
Renn, Jenn-Huei [1 ]
机构
[1] Kaohsiung Vet Gen Hosp, Dept Orthopaed, Kaohsiung 81346, Taiwan
关键词
LESS INVASIVE STABILIZATION; FIXATION; COMPLICATIONS;
D O I
10.1186/s13018-014-0062-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Background: Tibial plateau fracture (TPF) includes different fracture patterns with varied degrees of articular depression and displacement. Many kinds of fixators, including newly designed plate with locking screws, were applied to treat these complicated fractures. We intended to follow up the surgical outcomes of (1) unilateral locking plate, (2) classic dual plates, or (3) hybrid dual plates for TPF. Materials and methods: We retrospectively reviewed 76 patients with TPF, Schatzker types V and VI, who we operated from June 2006 to May 2009 in our institute. Excluding patients who expired due to other medical conditions and without complete follow-up, 45 patients were sorted out in this series. The scheme of surgical intervention was designed by visiting staff, and 15 patients, as group I, were treated with unilateral locking plate. The other 19 patients, as group II, were treated with classic dual plates. The residual 11 patients, as group III, were treated with hybrid dual plates (one lateral approach locking compression plate (LCP) + medial anti-gliding plate). All patients were under periodic F/U at about 6 weeks interval for at least 18 months postoperatively. Results: In group I, 13 cases achieved solid bony union without obvious traumatic OA change, limitation of ROM, or malalignment. In groups II and III, 15 and 10 patients reached the same goal, respectively. By analysis of the recorded parameters with statistical software (SPSS 12.0), there were five parameters with significant difference, including Schatzker classification, operation time, staged treatment or not, hospitalization period, and hardware impingement. Conclusions: There was no significant statistical difference of union rate between these three groups in our series. Based on our clinical follow-up, several key points were emphasized: (1) Soft tissue problems should be kept in mind, and usage of locking plate can reduce the discomfort of hardware impingement effectively. (2) The single lateral approach technique for TPF with locking plate results in less operation time and shorter hospitalization period. (3) If the medial buttress cannot be established by reduction of the lateral fracture, then open reduction of the medial side is necessary and buttresses the medial fragment by dual plates.
引用
收藏
页数:8
相关论文
共 18 条
[1]
Ali A M, 2001, Injury, V32 Suppl 4, pSD86
[2]
Failure of fixation of tibial plateau fractures [J].
Ali, AM ;
El-Shafie, M ;
Willett, KM .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2002, 16 (05) :323-329
[3]
Modified hybrid fixator for high-energy Schatzker V and VI tibial plateau fractures [J].
Ariffin, Hisam Muhamad ;
Mahdi, Nidzwani M. ;
Rhani, Shaharuddin A. ;
Baharudin, Azmi ;
Shukur, Mohamad Hassan .
STRATEGIES IN TRAUMA AND LIMB RECONSTRUCTION, 2011, 6 (01) :21-26
[4]
INJURY SEVERITY SCORE - METHOD FOR DESCRIBING PATIENTS WITH MULTIPLE INJURIES AND EVALUATING EMERGENCY CARE [J].
BAKER, SP ;
ONEILL, B ;
HADDON, W ;
LONG, WB .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1974, 14 (03) :187-196
[5]
Frequency and fracture morphology of the posteromedial fragment in bicondylar tibial plateau fracture patterns [J].
Barei, David P. ;
O'Mara, Timothy J. ;
Taitsman, Lisa A. ;
Dunbar, Robert P. ;
Nork, Sean E. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (03) :176-182
[6]
Functional outcomes of severe bicondylar plateau fractures treated with dual incisions and medial and lateral plates [J].
Barei, David P. ;
Nork, Sean E. ;
Mills, William J. ;
Coles, Chad P. ;
Henley, M. Bradford ;
Benirschke, Stephen K. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (08) :1713-1721
[7]
Complications associated with internal fixation of high-energy bicondylar tibial plateau fractures utilizing a two-incision technique [J].
Barei, DP ;
Nork, SE ;
Mills, WJ ;
Henley, MB ;
Benirschke, SK .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (10) :649-657
[8]
Open reduction and internal fixation compared with circular fixator application for bicondylar tibial plateau fractures - Results of a multicenter, prospective, randomized clinical trial [J].
McKee M.D. ;
Pirani S.P. ;
Stephen D.J.G. ;
Feibel R. ;
Powell J.N. ;
McCormack R. ;
Schemitsch E.H. ;
Kreder H.J. ;
Sekeramayi F. ;
Zomar M. ;
Wild L.M. ;
Buckley R. ;
Richards R.R. ;
Waddell J.P. ;
Daniels T.R. ;
Bogoch E.R. ;
Finkelstein J. ;
Axelrod T. ;
Perey B. ;
MacPherson H. ;
Goetz T. ;
Pate G. ;
Penner M. ;
Giachino A. ;
Barei D. ;
Veri J.-P. ;
Bulmer B. ;
Conlin L. ;
Elves L. ;
Erho C. ;
Moon K. ;
Kimmel E. ;
Conway A. ;
Hrushowy H. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (12) :2613-2623
[9]
Cole P., 2009, Skeletal Trauma: Basic Science Management and Reconstruction, P2201, DOI [10.1016/b978-1-4160-2220-6.10056-8, DOI 10.1016/B978-1-4160-2220-6.10056-8]
[10]
Treatment of complex tibial plateau fractures using the less invasive stabilization system plate: Clinical experience and a laboratory comparison with double plating [J].
Egol, KA ;
Su, E ;
Tejwani, NC ;
Sims, SH ;
Kummer, FJ ;
Koval, KJ .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2004, 57 (02) :340-346