Differential scanning calorimetric studies of nickel-titanium rotary endodontic instruments after simulated clinical use

被引:36
作者
Brantley, WA
Svec, TA [1 ]
Iijima, M
Powers, JM
Grentzer, TH
机构
[1] Univ Texas, Dent Branch, Div Endodont, Hlth Sci Ctr,Dept Stomatol, Houston, TX 77030 USA
[2] Ohio State Univ, Sect Restorat Dent Prosthodont & Endodont, Coll Dent, Columbus, OH 43210 USA
[3] Ohio State Univ, Grad Program Dent Mat Sci, Coll Dent, Columbus, OH 43210 USA
[4] Hlth Sci Univ Hokkaido, Dept Orthodont, Sch Dent, Ishikari, Hokkaido 06102, Japan
[5] Univ Texas, Dent Branch, Hlth Sci Ctr, Dept Restorat Dent & Biomat, Houston, TX 77030 USA
[6] Univ Texas, Dent Branch, Hlth Sci Ctr, Houston Biomat Res Ctr, Houston, TX 77030 USA
[7] Univ Texas, Dent Branch, Hlth Sci Ctr, Grad Program Dent Mat Sci, Houston, TX 77030 USA
关键词
D O I
10.1097/00004770-200211000-00007
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Differential scanning calorimetric (DSC) analyses have been performed between - 130degrees and 100degreesC on single-segment specimens obtained from ProFile and Lightspeed nickel-titanium rotary endodontic instruments in the as-received condition and after one, three, and six periods of simulated clinical use in extracted teeth. The DSC analyses showed that both brands of instruments were always in the superelastic condition, although the enthalpy values for the transformation from martensitic NiTi to austenitic NiTi were much smaller for the Lightspeed instruments. Simulated clinical use had no evident effect upon this transformation for both brands, which is attributed to insufficient mechanical deformation of the instruments. There were substantial differences in the enthalpy change associated with the transformation from martensitic NiTi to austenitic NiTi for test segments from different positions along the shafts of the instruments and for as-received instruments from two different batches that were analyzed in this study and a previous study. These differences are attributed to variations in work hardening along the shaft during instrument fabrication and to processing differences during production of the two batches of each instrument brand.
引用
收藏
页码:774 / 778
页数:5
相关论文
共 20 条
[1]  
ANDREASEN GF, 1978, AM J ORTHOD DENTOFAC, V73, P141, DOI 10.1016/0002-9416(78)90184-7
[2]   Differential scanning calorimetry (DSC) analyses of superelastic and nonsuperelastic nickel-titanium orthodontic wires [J].
Bradley, TG ;
Brantley, WA ;
Culbertson, BM .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1996, 109 (06) :589-597
[3]  
Brantley W.A., 2001, Thieme., P77
[4]  
BRANTLEY WA, IN PRESS J ENDODON
[5]   Shaping ability of .04 and .06 taper ProFile rotary nickel-titanium instruments in simulated root canals [J].
Bryant, ST ;
Dummer, PMH ;
Pitoni, C ;
Bourba, M ;
Moghal, S .
INTERNATIONAL ENDODONTIC JOURNAL, 1999, 32 (03) :155-164
[6]   A comparison of molar root canal preparation using stainless-steel and nickel-titanium instruments [J].
Carvalho, LAP ;
Bonetti, I ;
Borges, MAG .
JOURNAL OF ENDODONTICS, 1999, 25 (12) :807-810
[7]   POTENTIAL APPLICATIONS OF CERTAIN NICKEL-TITANIUM (NITINOL) ALLOYS [J].
CIVJAN, S ;
HUGET, EF ;
DESIMON, LB .
JOURNAL OF DENTAL RESEARCH, 1975, 54 (01) :89-96
[8]   Wear of nickel-titanium lightspeed instruments evaluated by scanning electron microscopy [J].
Eggert, C ;
Peters, O ;
Barbakow, F .
JOURNAL OF ENDODONTICS, 1999, 25 (07) :494-497
[9]   BENDING PROPERTIES OF SUPERELASTIC AND NONSUPERELASTIC NICKEL-TITANIUM ORTHODONTIC WIRES [J].
KHIER, SE ;
BRANTLEY, WA ;
FOURNELLE, RA .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1991, 99 (04) :310-318
[10]   THE SUPER-ELASTIC PROPERTY OF THE JAPANESE NITI ALLOY WIRE FOR USE IN ORTHODONTICS [J].
MIURA, F ;
MOGI, M ;
OHURA, Y ;
HAMANAKA, H .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1986, 90 (01) :1-10