Photocrosslinking characteristics and mechanical properties of diethyl fumarate/poly(propylene fumarate) biomaterials

被引:178
作者
Fisher, JP
Dean, D
Mikos, AG
机构
[1] Rice Univ, Dept Bioengn, Houston, TX 77251 USA
[2] Univ Hosp Cleveland, Dept Neurol Surg, Cleveland, OH 44106 USA
[3] Univ Hosp Cleveland, Res Inst, Cleveland, OH 44106 USA
[4] Case Western Reserve Univ, Dept Neurol Surg, Cleveland, OH 44106 USA
关键词
diethyl fumarate; poly(propylene fumarate); photocrosslinking; tissue engineering; injectable biomaterials;
D O I
10.1016/S0142-9612(02)00178-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
The development of tissue engineered materials for the treatment of large bone defects would provide attractive alternatives to the autografts, allografts, non-degradable polymers, ceramics, and metals that are currently used in clinical settings. To this end, poly(propylene fumarate) (PPF), a viscous polyester synthesized from diethyl fumarate (DEF), has been studied for use as an engineered bone graft. We have investigated the photocrosslinking of PPF dissolved in its precursor, DEF, using the photoinitiator bis(2,4,6-trimethylbenzoyl) phenylphosphine oxide (BAPO) and low levels of ultraviolet light exposure. A three factor, 2 x 2 x 4 factorial design was developed, studying the effects of PPF number average molecular weight, BAPO initiator content, and DEF content upon photocrosslinking characteristics and mechanical properties. Uncured DEF/PPF solution viscosity fell over three orders of magnitude as DEF content was increased from 0% to 75%. The exothermic photocrosslinking reaction released low levels of heat, with no more than 160 J/g released from any formulation tested. As a result, the maximum photocrosslinking temperature remained below 47degreesC for all samples. Both sol fraction and swelling degree generally increased with increasing DEF content. Compressive mechanical properties were within the range of trabecular bone, with the strongest samples possessing an elastic modulus of 195.3 +/- 17.5 MPa and a fracture strength of 68.8 +/- 9.4 MPa. Finally, the results indicate that PPF crosslinking was facilitated at low DEF precursor concentrations, but hindered at higher precursor concentrations. These novel DEF/PPF solutions may be preferred over pure PPF as the basis for an engineered bone graft because they (1) exhibit reduced viscosity and thus are easily handled, (2) form polymer networks with compressive strength at fracture suitable for consideration for trabecular bone replacement, and (3) may be readily fabricated into solids with a wide range of structures. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:4333 / 4343
页数:11
相关论文
共 22 条
[1]
Fundamentals of biomechanics in tissue engineering of bone [J].
Athanasiou, KA ;
Zhu, CF ;
Lanctot, DR ;
Agrawal, CM ;
Wang, X .
TISSUE ENGINEERING, 2000, 6 (04) :361-381
[2]
Brandrup J, 1989, POLYM HDB
[3]
THERMAL-INJURY TO BONE - A VITAL-MICROSCOPIC DESCRIPTION OF HEAT-EFFECTS [J].
ERIKSSON, A ;
ALBREKTSSON, T ;
GRANE, B ;
MCQUEEN, D .
INTERNATIONAL JOURNAL OF ORAL SURGERY, 1982, 11 (02) :115-121
[4]
Soft and hard tissue response to photocrosslinked poly(propylene fumarate) scaffolds in a rabbit model [J].
Fisher, JP ;
Vehof, JWM ;
Dean, D ;
van der Waerden, JPCM ;
Holland, TA ;
Mikos, AG ;
Jansen, JA .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2002, 59 (03) :547-556
[5]
Photoinitiated polymerization of biomaterials [J].
Fisher, JP ;
Dean, D ;
Engel, PS ;
Mikos, AG .
ANNUAL REVIEW OF MATERIALS RESEARCH, 2001, 31 (31) :171-181
[6]
Fisher JP, 2001, J BIOMAT SCI-POLYM E, V12, P673
[7]
Biomechanical and histological evaluation of a calcium phosphate cement [J].
Frankenburg, EP ;
Goldstein, SA ;
Bauer, TW ;
Harris, SA ;
Poser, RD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (08) :1112-1124
[8]
Gauthier O, 1999, J BIOMED MATER RES, V47, P28, DOI 10.1002/(SICI)1097-4636(199910)47:1<28::AID-JBM4>3.0.CO
[9]
2-P
[10]
Grimandi G, 1998, J BIOMED MATER RES, V39, P660, DOI 10.1002/(SICI)1097-4636(19980315)39:4<660::AID-JBM22>3.0.CO