CO2 digital subtraction angiography for renal artery angioplasty in high-risk patients

被引:32
作者
Caridi, JG [1 ]
Stavropoulos, SW [1 ]
Hawkins, IF [1 ]
机构
[1] Univ Florida, Coll Med, Dept Radiol, Gainesville, FL 32610 USA
关键词
D O I
10.2214/ajr.173.6.10584800
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The efficacy of CO2 digital subtraction angiography for performing renal artery angioplasty in high-risk patients was evaluated. SUBJECTS AND METHODS. From January 1997 to July 1998, 21 high-risk patients underwent 29 renal artery angioplasties using carbon dioxide as the principal contrast agent. Six patients had a known allergy to iodinated contrast material and 15 had elevated levels of creatinine. Iodinated contrast material was used only if necessary. All periprocedural allergic reactions were recorded. Before and 24 hr after the procedure, serum creatinine levels were obtained. If the creatinine level had become significantly elevated (>0.5 mg/dl), the creatinine level was acquired a second time. RESULTS. Twenty-one patients (13 men and eight women) underwent 29 angioplasties (two were bilateral and six were repeated). Four kidney transplantation patients had ostial stenosis and the remaining 17 patients had nonostial stenosis. For all patients except one angioplasty initially was a technical success, as defined by a residual stenosis of less than 30%. Supplemental iodinated contrast material was used in only six patients (average dose, 8.5 ml). A range of 80-200 ml of carbon dioxide per procedure was used (average dose, (114.6 ml). One renal artery dissection occurred, which was unrelated to the carbon dioxide. There were no allergic reactions. The level of serum creatinine remained the same after 11 procedures, decreased after 12 procedures, and increased minimally after four procedures (<0.5 mg/dl). CONCLUSION. On the basis of our preliminary findings in a small group of patients, using carbon dioxide as an intravascular contrast agent to perform renal artery angioplasty in patients who have an allergy to iodinated contrast material or who suffer from renal insufficiency is safe and efficacious.
引用
收藏
页码:1551 / 1556
页数:6
相关论文
共 34 条
  • [1] BEREGI JP, 1996, AJR, V167, P485
  • [2] CARIDI JG, 1997, J VASC INTERV RADIOL, V14, P175
  • [3] ESHELMAN DJ, 1998, AJR, V171, P1265
  • [4] RENOVASCULAR OCCLUSIVE DISEASE - RESULTS OF OPERATIVE TREATMENT
    FOSTER, JH
    MAXWELL, MH
    FRANKLIN, SS
    BLEIFER, KH
    TRIPPEL, OH
    JULIAN, OC
    DECAMP, PT
    VARADY, PT
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1975, 231 (10): : 1043 - 1048
  • [5] CARBON-DIOXIDE DIGITAL SUBTRACTION ARTERIOGRAPHY-ASSISTED TRANSLUMINAL ANGIOPLASTY
    FRANKHOUSE, JH
    RYAN, MG
    PAPANICOLAOU, G
    YELLIN, AE
    WEAVER, FA
    [J]. ANNALS OF VASCULAR SURGERY, 1995, 9 (05) : 448 - 452
  • [6] TRANSIENT REDUCTION IN RENAL-FUNCTION FOLLOWING ARTERIOGRAPHY - A RADIONUCLIDE STUDY
    GATES, GF
    GREEN, GS
    [J]. JOURNAL OF UROLOGY, 1983, 129 (06) : 1107 - 1110
  • [7] Acute renal failure after arteriography with a gadolinium-based contrast agent
    Gemery, J
    Idelson, B
    Reid, S
    Yucel, EK
    Pagan-Marin, H
    Ali, S
    Casserly, L
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (05) : 1277 - 1278
  • [8] EVALUATION OF HYPERTENSIVE PATIENT WITH EMPHASIS ON DETECTING CURABLE CAUSES
    GIFFORD, RW
    [J]. MILBANK MEMORIAL FUND QUARTERLY-HEALTH AND SOCIETY, 1969, 47 (03): : 170 - 186
  • [9] PERCUTANEOUS TRANS-LUMINAL DILATATION IN THE TREATMENT OF RENAL VASCULAR HYPERTENSION
    GRIM, CE
    LUFT, FC
    YUNE, HY
    KLATTE, EC
    WEINBERGER, MH
    [J]. ANNALS OF INTERNAL MEDICINE, 1981, 95 (04) : 439 - 442
  • [10] GRUNTZIG A, 1978, LANCET, V1, P801