Amperometric biosensors employing an insoluble oxidant as an interference-removing agent

被引:39
作者
Choi, SH [1 ]
Lee, SD [1 ]
Shin, JH [1 ]
Ha, J [1 ]
Nam, H [1 ]
Cha, GS [1 ]
机构
[1] Kwangwoon Univ, Dept Chem, Chem Sensor Res Grp, Seoul 139701, South Korea
关键词
biosensors; creatinine; glucose; interference;
D O I
10.1016/S0003-2670(02)00281-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A strong oxidant membrane is introduced to amperometric biosensors in order to solve the problem associated with interference from readily oxidizable species. The proposed biosensors are in planar format, and are composed of four components, i.e. a base amperometric transducer, an enzyme layer, a protecting membrane, and an oxidant membrane. In this sensor format, interfering species are removed by an oxidation reaction during their diffusion through the oxidant membrane. The oxidant membrane is introduced by dispensing a mixture of an oxidant and a polymer matrix as dissolved in an organic solvent, and thus, could be easily adapted to mass fabrication of miniature biosensors. In this work, several different reagents are examined as oxidants: BaO2, CeO2, MnO2 and PbO2. Of these, PbO2 is shown to yield biosensors with the best performance, in terms of reducing interfering signals. Two different matrix systems are devised for use in formulating oxidant membranes: hydrophilic polyurethane (HPU) and cellulose acetate incorporating poly(ethylene glycol) (CA/PEG). While the CA/PEG-type sensor displays better sensitivity and faster response behavior, the HPU-type is shown to exhibit more pronounced interference-removing ability. The analytical utility of the proposed oxidant membrane is demonstrated by fabricating amperometric glucose and creatinine sensors as the model biosensor systems, and by investigating their response characteristics. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:251 / 260
页数:10
相关论文
共 40 条
[11]   A highly sensitive amperometric creatinine sensor [J].
Khan, GF ;
Wernet, W .
ANALYTICA CHIMICA ACTA, 1997, 351 (1-3) :151-158
[12]   Peroxidase-based amperometric sensor of hydrogen peroxide generated in oxidase reaction: Application to creatinine and creatine assay [J].
Kinoshita, H ;
Torimura, M ;
Kano, K ;
Ikeda, T .
ELECTROANALYSIS, 1997, 9 (16) :1234-1238
[13]   Microfabricated biosensors and microanalytical systems for blood analysis [J].
Lauks, IR .
ACCOUNTS OF CHEMICAL RESEARCH, 1998, 31 (05) :317-324
[14]  
Lee JS, 1999, ELECTROANAL, V11, P260, DOI 10.1002/(SICI)1521-4109(199904)11:4<260::AID-ELAN260>3.0.CO
[15]  
2-#
[16]   Chromium hexacyanoferrate based glucose biosensor [J].
Lin, MS ;
Shih, WC .
ANALYTICA CHIMICA ACTA, 1999, 381 (2-3) :183-189
[17]   Miniaturized biosensors employing electropolymerized permselective films and their use for creatinine assays in human serum [J].
Madaras, MB ;
Buck, RP .
ANALYTICAL CHEMISTRY, 1996, 68 (21) :3832-3839
[18]   Microfabricated amperometric creatine and creatinine biosensors [J].
Madaras, MB ;
Popescu, IC ;
Ufer, S ;
Buck, RP .
ANALYTICA CHIMICA ACTA, 1996, 319 (03) :335-345
[19]   GALACTOSE BIOSENSORS USING COMPOSITE POLYMERS TO PREVENT INTERFERENCES [J].
MANOWITZ, P ;
STOECKER, PW ;
YACYNYCH, AM .
BIOSENSORS & BIOELECTRONICS, 1995, 10 (3-4) :359-370
[20]   Glucose determination in blood samples using flow injection analysis and an amperometric biosensor based on glucose oxidase immobilized on hexacyanoferrate modified nickel electrode [J].
Milardovic, S ;
Kruhak, I ;
Ivekovic, D ;
Rumenjak, V ;
Tkalcec, M ;
Grabaric, BS .
ANALYTICA CHIMICA ACTA, 1997, 350 (1-2) :91-96