MR imaging of the lungs with hyperpolarized helium-3 gas transported by air

被引:37
作者
Wild, JM
Schmiedeskamp, J
Paley, MNJ
Filbir, F
Fichele, S
Kasuboski, L
Knitz, F
Woodhouse, N
Swift, A
Hei, W
Mills, GH
Wolf, M
Griffiths, PD
Otten, E
van Beek, EJR
机构
[1] Univ Sheffield, Royal Hallamshire Hosp, Acad Unit Radiol, Sheffield S10 2JF, S Yorkshire, England
[2] Univ Mainz, Inst Phys, D-6500 Mainz, Germany
[3] Philips Med, Cleveland, OH USA
[4] Univ Mainz, Unit Anaesthesiol, D-6500 Mainz, Germany
[5] Univ Sheffield, Royal Hallamshire Hosp, Dept Anaesthesiol, Sheffield S10 2JF, S Yorkshire, England
关键词
D O I
10.1088/0031-9155/47/13/401
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Hyperpolarized noble gas MRI shows promise in the functional imaging of the pulmonary air spaces. The production of hyperpolarized (HP) gas requires specialized laser optical pumping apparatus, which is riot likely to be home built in the majority of clinical MRI radiology centres. There are two routes through which HP gas will be made available to hospitals for clinical use: either the apparatus will be installed locally at a considerable expense to the centre, or a central facility will produce the gas and then deliver it to remote MRI sites as and when required. In this study, the feasibility of transporting large quantities of HP gas for in vivo MR imaging from a remote production facility in Mainz, Germany, by airfreight to Sheffield, UK, was successfully demonstrated.
引用
收藏
页码:N185 / N190
页数:6
相关论文
共 10 条
[1]   STUDY OF MECHANICAL COMPRESSION OF SPIN-POLARIZED HE-3 GAS [J].
BECKER, J ;
HEIL, W ;
KRUG, B ;
LEDUC, M ;
MEYERHOFF, M ;
NACHER, PJ ;
OTTEN, EW ;
PROKSCHA, T ;
SCHEARER, LD ;
SURKAU, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 346 (1-2) :45-51
[2]   Interdisciplinary experiments with polarized 3He [J].
Becker, J ;
Bermuth, J ;
Ebert, M ;
Grossmann, T ;
Heil, W ;
Hofmann, D ;
Humblot, H ;
Leduc, M ;
Otten, EW ;
Rohe, D ;
Surkau, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 402 (2-3) :327-336
[3]   POLARIZATION OF HE3 GAS BY OPTICAL PUMPING [J].
COLEGROVE, FD ;
SCHEARER, LD ;
WALTERS, GK .
PHYSICAL REVIEW, 1963, 132 (06) :2561-&
[4]   Analysis of intrapulmonary O2 concentration by NIR imaging of inhaled hyperpolarized helium-3 [J].
Eberle, B ;
Weiler, N ;
Markstaller, K ;
Kauczor, HU ;
Deninger, A ;
Ebert, M ;
Grossmann, T ;
Heil, W ;
Lauer, LO ;
Roberts, TPL ;
Schreiber, WG ;
Surkau, R ;
Dick, WF ;
Otten, EW ;
Thelen, M .
JOURNAL OF APPLIED PHYSIOLOGY, 1999, 87 (06) :2043-2052
[5]   Nuclear magnetic resonance imaging with hyperpolarised helium-3 [J].
Ebert, M ;
Grossmann, T ;
Heil, W ;
Otten, WE ;
Surkau, R ;
Leduc, M ;
Bachert, P ;
Knopp, MV ;
Schad, LR ;
Thelen, M .
LANCET, 1996, 347 (9011) :1297-1299
[6]   RAPID NMR IMAGING OF DYNAMIC PROCESSES USING THE FLASH TECHNIQUE [J].
FRAHM, J ;
HAASE, A ;
MATTHAEI, D .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (02) :321-327
[7]  
GROSSMANN T, 2000, THESIS U MAINZ
[8]   POLARIZATION OF THE NUCLEAR SPINS OF NOBLE-GAS ATOMS BY SPIN EXCHANGE WITH OPTICALLY PUMPED ALKALI-METAL ATOMS [J].
HAPPER, W ;
MIRON, E ;
SCHAEFER, S ;
SCHREIBER, D ;
VANWIJNGAARDEN, WA ;
ZENG, X .
PHYSICAL REVIEW A, 1984, 29 (06) :3092-3110
[9]   VERY LONG NUCLEAR-RELAXATION TIMES OF SPIN-POLARIZED HELIUM-3 IN METAL-COATED CELLS [J].
HEIL, W ;
HUMBLOT, H ;
OTTEN, E ;
SCHAFER, M ;
SARKAU, R ;
LEDUC, M .
PHYSICS LETTERS A, 1995, 201 (04) :337-343
[10]   k-space filtering in 2D gradient-echo breath-hold hyperpolarized 3He MRI:: Spatial resolution and signal-to-noise ratio considerations [J].
Wild, JM ;
Paley, MNJ ;
Viallon, M ;
Schreiber, WG ;
van Beek, EJR ;
Griffiths, PD .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (04) :687-695