Accurate measurements of local skin friction coefficient using hot-wire anemometry

被引:82
作者
Hutchins, N [1 ]
Choi, KS [1 ]
机构
[1] Univ Nottingham, Sch Mech Mat Mfg Engn & Management, Nottingham NG7 2RD, England
基金
英国工程与自然科学研究理事会;
关键词
D O I
10.1016/S0376-0421(02)00027-1
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
The practicality and accuracy of many existing methods of local skin friction measurement suffer when the boundary layer flow under consideration is non-canonical. Such shortcomings are exacerbated in three-dimensional flows, by the necessity to map local c(f) over a wider area in order to characterise fully the contribution to global skin friction. These problems have led the authors to seek novel experimental methods of c(f) measurement. The technique proposed herein utilises velocity measurements made using hot-wire anemometry combined with accurate positioning of the sensor element in respect to the test surface. In essence it is proposed that the local skin friction can be evaluated via a single velocity measurement made at a known wall-normal distance within the linear region of the viscous sublayer. This technique relies on accurate probe positioning, and two methods of achieving this are outlined. A study of the hot-wire characteristics in near-wall proximity has revealed a previously unnoticed feature corresponding to probe-wall contact. It is shown that this anomaly can be used as a positional flag to accurately locate the aerodynamic origin of the hot-wire sensor. A second technique using a laser triangulation displacement sensor is also outlined. Both positional techniques are shown to offer positioning to a sufficient level of accuracy for the proposed c(f) measurement technique. Single-point local c(f) measurement is tested experimentally, demonstrating the improved repeatability and standard error as predicted by initial error analysis. In this way it is shown that a single 90 s velocity sample coupled with accurate wall positioning can define local c(f) to a standard error of sigma(cf) approximate to 1.0%. Analysis of error contributions reveals that longer sampling periods can realise even greater accuracy. The proposed technique is also used to measure local c(f) in a three-dimensional boundary layer where micro-vortex generators have introduced large-scale spanwise distortions. This is an example of an application in a non-canonical boundary layer, and initial results show that the method is capable of providing repeatable comparative spanwise-averaged skin friction results to within approximately +/- 1%. The technique is immediately applicable to researchers using hot-wire anemometry in low Reynolds number flow over electrically non-conductive test surfaces. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:421 / 446
页数:26
相关论文
共 48 条
[1]  
ANDERS JB, 1989, VISCOUS DRAG REDUCTI, P203
[2]  
AZAD RS, 1983, EXP FLUIDS, V1, P149
[3]   CORRECTIONS OF HOT-WIRE ANEMOMETER MEASUREMENTS NEAR WALLS [J].
BHATIA, JC ;
DURST, F ;
JOVANOVIC, J .
JOURNAL OF FLUID MECHANICS, 1982, 122 (SEP) :411-431
[4]  
Box G.E., 1978, STAT EXPT
[5]  
BROWN GL, 1967, P HEAT TRANSFER FLUI, P361
[6]  
Bruun H. H., 1995, HOT WIRE ANEMOMETRY
[7]   Directional sensitivity of skin friction measurements using nematic liquid crystal [J].
Buttsworth, DR ;
Elston, SJ ;
Jones, TV .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1998, 9 (11) :1856-1865
[8]   Direct full surface skin friction measurement using nematic liquid crystal techniques [J].
Buttsworth, DR ;
Elston, SJ ;
Jones, TV .
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 1998, 120 (04) :847-853
[9]   On the numerical near-wall corrections of single hot-wire measurements [J].
Chew, YT ;
Shi, SX ;
Khoo, BC .
INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 1995, 16 (06) :471-476
[10]   An investigation of wall effects on hot-wire measurements using a bent sublayer probe [J].
Chew, YT ;
Khoo, BC ;
Li, GL .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1998, 9 (01) :67-85