Pressure-sensitive paint measurements in a shock tube

被引:23
作者
Hubner, JP
Carroll, BF
Schanze, KS
Ji, HF
机构
[1] Univ Florida, Dept Aerosp Engn Mech & Engn Sci, Gainesville, FL 32611 USA
[2] Univ Florida, Dept Chem, Gainesville, FL 32611 USA
关键词
D O I
10.1007/s003480050003
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Surface pressures were measured in the short-duration, transient flow environment of a small-scale, low pressure-ratio shock tube using thin-film pressure-sensitive paint (PSP). Issues regarding coating formulation, measurement uncertainty, optical system design, and temperature and illumination compensation are discussed. The pressure measurements were acquired during steady flow conditions following the passage of normal shocks and expansion regions along a flat sidewall and a wedge sidewall. The PSP characteristic response time was 3 to 6 ms. Overall pressure uncertainty for the shock tube measurements ranged up to 5% over one atmosphere and compared well with theoretical estimates of uncertainty.
引用
收藏
页码:21 / 28
页数:8
相关论文
共 13 条
[1]   SUBMILLISECOND RESPONSE-TIMES OF OXYGEN-QUENCHED LUMINESCENT COATINGS [J].
BARON, AE ;
DANIELSON, JDS ;
GOUTERMAN, M ;
WAN, JR ;
CALLIS, JB ;
MCLACHLAN, B .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (12) :3394-3402
[2]  
BOROVOY V, 1995, 16 ICIASF REC
[3]   Step response of pressure-sensitive paints [J].
Carroll, BF ;
Abbitt, JD ;
Lukas, EW ;
Morris, MJ .
AIAA JOURNAL, 1996, 34 (03) :521-526
[4]   Application of dual sorption theory to pressure-sensitive paints [J].
Hubner, JP ;
Carroll, BF .
AIAA JOURNAL, 1997, 35 (11) :1790-1792
[5]  
LUI T, 1997, APPL MECH REV, V50, P227
[6]   PRESSURE-SENSITIVE PAINT IN AERODYNAMIC TESTING [J].
MCLACHLAN, BG ;
BELL, JH .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 1995, 10 (04) :470-485
[7]  
MENDOZA D, 1996, THESIS U CALIFORNIA
[8]   AERODYNAMIC APPLICATIONS OF PRESSURE SENSITIVE PAINT [J].
MORRIS, MJ ;
DONOVAN, JF ;
KEGELMAN, JT ;
SCHWAB, SD ;
LEVY, RL ;
CRITES, RC .
AIAA JOURNAL, 1993, 31 (03) :419-425
[9]  
Rogers C.E., 1985, Polymer Permeability, P11, DOI DOI 10.1007/978-94-009-4858-7_2
[10]   UNCERTAINTY ESTIMATES FOR PRESSURE-SENSITIVE PAINT MEASUREMENTS [J].
SAJBEN, M .