Peripheral doses in CyberKnife radiosurgery

被引:47
作者
Petti, Paula L. [1 ]
Chuang, Cynthia F. [1 ]
Smith, Vernon [1 ]
Larson, David A. [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA 94143 USA
关键词
D O I
10.1118/1.2198173
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this work is to measure the dose outside the treatment field for conformal CyberKnife treatments, to compare the results to those obtained for similar treatments delivered with gamma knife or intensity-modulated radiation therapy (IMRT), and to investigate the sources of peripheral dose in CyberKnife radiosurgery. CyberKnife treatment plans were developed for two hypothetical lesions in an anthropomorphic phantom, one in the thorax and another in the brain, and measurements were made with LiF thermoluminescent dosimeters (TLD-100 capsules) placed within the phantom at various depths and distances from the irradiated volume. For the brain lesion, gamma knife and 6-MV IMRT treatment plans were also developed, and peripheral doses were measured at the same locations as for the CyberKnife plan. The relative contribution to the CyberKnife peripheral dose from inferior- or superior-oblique beams entering or exiting through the body, internally scattered radiation, and leakage radiation was assessed through additional experiments using the single-isocenter option of the CyberKnife treatment-planning program with different size collimators. CyberKnife peripheral doses (in cGy) ranged from 0.16 to 0.041% (+/- 0.003 %) of the delivered number of monitor units (MU) at distances between 18 and 71 cm from the field edge. These values are two to five times larger than those measured for the comparable gamma knife brain treatment, and up to a factor of four times larger those measured in the IMRT experiment. Our results indicate that the CyberKnife peripheral dose is due largely to leakage radiation, however at distances less than 40 cm from the field edge, entrance, or exit dose from inferior- or superior-oblique beams can also contribute significantly. For distances larger than 40 cm from the field edge, the CyberKnife peripheral dose is directly related to the number of MU delivered, since leakage radiation is the dominant component. (C) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:1770 / 1779
页数:10
相关论文
共 10 条
[1]  
[Anonymous], 2005, HLTH RISKS EXPOSURE
[2]   Cancer risks attributable to low doses of ionizing radiation: Assessing what we really know [J].
Brenner, DJ ;
Doll, R ;
Goodhead, DT ;
Hall, EJ ;
Land, CE ;
Little, JB ;
Lubin, JH ;
Preston, DL ;
Preston, RJ ;
Puskin, JS ;
Ron, E ;
Sachs, RK ;
Samet, JM ;
Setlow, RB ;
Zaider, M .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2003, 100 (24) :13761-13766
[3]   Measurements of extracranial doses in patients treated with Leksell Gamma Knife C [J].
De Smedt, F ;
Vanderlinden, B ;
Simon, S ;
Paesmans, M ;
Devriendt, D ;
Massager, N ;
Ruiz, S ;
Lorenzoni, J ;
Van Houtte, P ;
Brotchi, J ;
Levivier, M .
RADIOSUGERY, VOL 5, 2004, 5 :197-212
[4]   PERIPHERAL DOSE FROM MEGAVOLT BEAMS [J].
FRAASS, BA ;
VANDEGEIJN, J .
MEDICAL PHYSICS, 1983, 10 (06) :809-818
[5]   Fetal and ovarian radiation dose in patients undergoing gamma knife radiosurgery [J].
Ioffe, V ;
Hudes, RS ;
Shepard, D ;
Simard, JM ;
Chin, LS ;
Yu, C .
SURGICAL NEUROLOGY, 2002, 58 (01) :32-41
[6]  
National Council on Radiation Protection and Measurements (NCRP), 1976, STRUCT SHIELD DES EV, V49
[7]   Estimation of radiation-induced cancer from three-dimensional dose distributions: Concept of organ equivalent dose [J].
Schneider, U ;
Zwahlen, D ;
Ross, D ;
Kaser-Hotz, B .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (05) :1510-1515
[8]   FETAL DOSE FROM RADIOTHERAPY WITH PHOTON BEAMS - REPORT OF AAPM-RADIATION-THERAPY-COMMITTEE TASK GROUP NO-36 [J].
STOVALL, M ;
BALCKWELL, CR ;
CUNDIFF, J ;
NOVACK, DH ;
PALTA, JR ;
WAGNER, LK ;
WEBSTER, EW ;
SHALEK, RJ .
MEDICAL PHYSICS, 1995, 22 (01) :63-82
[9]   The cancer epidemiology of radiation [J].
Wakeford, R .
ONCOGENE, 2004, 23 (38) :6404-6428
[10]   Fetal radiation doses for model C gamma knife radiosurgery [J].
Yu, C ;
Jozsef, G ;
Apuzzo, MLJ ;
MacPherson, DM ;
Petrovich, Z .
NEUROSURGERY, 2003, 52 (03) :687-693