A simple and robust method for designing a multi-loop controller for three-phase VSI with an LCL-filter under uncertain system parameters

被引:19
作者
Trung Nhan Nguyen [1 ,2 ]
Luo, An [2 ]
Li, Mingfei [2 ]
机构
[1] Ind Univ Ho Chi Minh City, Fac Elect Engn, Ho Chi Minh City, Vietnam
[2] Hunan Univ, Sch Elect & Informat Engn, Changsha 410082, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Voltage source inverter; LCL-filter; Stability criterion; Control quality; Microgrid; Renewable energy; GRID-CONNECTED INVERTERS; VOLTAGE-SOURCE INVERTER; DISTRIBUTED GENERATION; STABILITY ANALYSIS; QUALITY;
D O I
10.1016/j.epsr.2014.08.011
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
080906 [电磁信息功能材料与结构]; 082806 [农业信息与电气工程];
摘要
Voltage source inverters (VSIs) with an LCL-filter are commonly used in practice, especially in microgrid systems. Exactly determining the control coefficients for the controller of a VSI with an LCL-filter is an important and challenging issue. However, existing LCL-filter-based inverter systems usually assume that all system parameters are determined accurately and remain constant overtime, which is not true in real situations. Variations in the system parameters are known to possibly seriously degrade the performance of LCL-filter-based inverter systems. For efficiency and robustness, this paper proposes a simple and robust method for the generalized controller design of a three-phase VSI with an LCL-filter system that can address deviations in system parameters. The proposed method can be effectively used to design the controller of an LCL-filter inverter system for fixed and varying system parameters. Simulations and experimental results are presented to validate the correctness and effectiveness of the proposed design method. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:94 / 103
页数:10
相关论文
共 25 条
[1]
El-Samahy I, 2005, IEEE POWER ENG SOC, P2969
[2]
Composite Nonlinear Feedback Control and Stability Analysis of a Grid-Connected Voltage Source Inverter With LCL Filter [J].
Eren, Suzan ;
Pahlevaninezhad, Majid ;
Bakhshai, Alireza ;
Jain, Praveen K. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (11) :5059-5074
[3]
Sensitivity Study of the Dynamics of Three-Phase Photovoltaic Inverters With an LCL Grid Filter [J].
Figueres, Emilio ;
Garcera, Gabriel ;
Sandia, Jesus ;
Gonzalez-Espin, Francisco ;
Calvo Rubio, Jesus .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (03) :706-717
[4]
GULLVIK W, 2007, P EUR C POW EL APPL, P1
[5]
A Sliding-Mode Controller With Multiresonant Sliding Surface for Single-Phase Grid-Connected VSI With an LCL Filter [J].
Hao, Xiang ;
Yang, Xu ;
Liu, Tao ;
Huang, Lang ;
Chen, Wenjie .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (05) :2259-2268
[6]
Weighted Average Current Control in a Three-Phase Grid Inverter With an LCL Filter [J].
He, Ning ;
Xu, Dehong ;
Zhu, Ye ;
Zhang, Jun ;
Shen, Guoqiao ;
Zhang, Yangfan ;
Ma, Jie ;
Liu, Changjin .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (06) :2785-2797
[7]
Performance Improvement of LCL-Filter-Based Grid-Connected Inverters Using PQR Power Transformation [J].
Jeong, Hea-Gwang ;
Lee, Kyo-Beum ;
Choi, Sewan ;
Choi, Woojin .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2010, 25 (05) :1320-1330
[8]
Robust proportional resonant regulator for grid-connected voltage source inverter (VSI) using direct pole placement design method [J].
Li, B. ;
Yao, W. ;
Hang, L. ;
Tolbert, L. M. .
IET POWER ELECTRONICS, 2012, 5 (08) :1367-1373
[9]
Full-Feedforward Schemes of Grid Voltages for a Three-Phase LCL-Type Grid-Connected Inverter [J].
Li, Weiwei ;
Ruan, Xinbo ;
Pan, Donghua ;
Wang, Xuehua .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (06) :2237-2250
[10]
Stability of photovoltaic and wind turbine grid-connected inverters for a large set of grid impedance values [J].
Liserre, M ;
Teodorescu, R ;
Blaabjerg, F .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2006, 21 (01) :263-272