Apoptosis in leucodepleted packed red blood cells

被引:15
作者
Bontadini, A [1 ]
Tazzari, PL [1 ]
Manfroi, S [1 ]
Tassi, C [1 ]
Conte, R [1 ]
机构
[1] Policlin S Orsola Malpighi, Serv Med Transfus, I-40138 Bologna, Italy
关键词
apoptosis; filtration; leucodepletion; packed red blood cells;
D O I
10.1046/j.1423-0410.2002.00191.x
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Background and Objectives Packed red blood cells (pRBCs) contain apoptotic white cells. We studied apoptotic cells in pRBCs after filtration and at various time-points during storage. Materials and Methods To maintain the same subset of cells, seven pRBC units were pooled in a single bag and divided equally into seven aliquots. Two series of five experiments were performed: in the first we utilized the Biofil R01 Max filter, and in the second the Pall BPF4 filter was used. One aliquot was immediately leucodepleted while the others were stored at 4 degreesC and filtered on days 3, 7, 10, 14, 21 and 42 of storage. The postfiltration leucocyte counts and apoptotic evaluations were performed by using the Nageotte chamber and flow cytometry. Results The absolute number of residual leucocytes was always less than 0.5 x 10(6) in each experiment. Nageotte chamber counts showed a greater number of white blood cells than flow cytometry during the 42 days of storage. On day 0, the percentage of apoptotic cells in non-leucodepleted pRBCs was 1.1 +/- 0.4 and 1.2 +/- 0.4, while in filtered pRBCs it was high from day 0, at 53.5 +/- 16.3 and 52 +/- 18.5, respectively, with Biofil and Pall filters. On day 10 of storage, apoptotic cells reached a percentage of 42.5 +/- 15.8 and 41.6 +/- 18.6 in non-leucodepleted pRBCs, while in filtered units an average value of approximate to 90% was found with both filters. Conclusions The percentage of apoptotic cells was higher in leucodepleted than in non-leucodepleted pRBCs. After filtration, the degree of apoptosis was already high on day 0, and reached a mean of approximate to 90% by day 10. The difference in residual WBC counts between the Nageotte chamber and flow cytometry could be related to the presence of a high percentage of apoptotic cells in filtered blood components, and to the method used to distinguish viable from apoptotic cells.
引用
收藏
页码:35 / 41
页数:7
相关论文
共 32 条
[1]
Morphological and biochemical characterization and analysis of apoptosis [J].
Allen, RT ;
Hunter, WJ ;
Agrawal, DK .
JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 1997, 37 (04) :215-228
[2]
A new tool in white blood cell reduction for packed red cells: 5 Log depletion [J].
Bontadini, A ;
Fruet, F ;
Conte, R .
TRANSFUSION MEDICINE, 1997, 7 (01) :29-32
[3]
COMPARATIVE-ANALYSIS OF 6 DIFFERENT WHITE CELL-REDUCTION FILTERS FOR PACKED RED-CELLS [J].
BONTADINI, A ;
FRUET, F ;
TAZZARI, PL ;
LOLLINI, PL ;
CONTE, R .
TRANSFUSION, 1994, 34 (06) :531-535
[4]
Bontadini A, 1999, INFUSIONSTHERAPIE, V26, P339
[5]
BORDIN JO, 1994, BLOOD, V84, P1703
[6]
A VERY SIMPLE METHOD FOR COUNTING WHITE CELLS IN PLATELET UNITS COLLECTED BY APHERESIS [J].
BORZINI, P ;
RIVA, M ;
DASSI, M ;
PROSERPIO, P ;
MESSINA, A ;
GANGI, L ;
GALESI, A ;
VILLA, T ;
SCIORELLI, G .
TRANSFUSION, 1995, 35 (10) :884-885
[7]
A COMPARISON OF FILTERED LEUKOCYTE-REDUCED AND CYTOMEGALOVIRUS (CMV) SERONEGATIVE BLOOD PRODUCTS FOR THE PREVENTION OF TRANSFUSION-ASSOCIATED CMV INFECTION AFTER MARROW TRANSPLANT [J].
BOWDEN, RA ;
SLICHTER, SJ ;
SAYERS, M ;
WEISDORF, D ;
CAYS, M ;
SCHOCH, G ;
BANAJI, M ;
HAAKE, R ;
WELK, K ;
FISHER, L ;
MCCULLOUGH, J ;
MILLER, W .
BLOOD, 1995, 86 (09) :3598-3603
[8]
ALLOIMMUNIZATION AFTER LEUKOCYTE-DEPLETED MULTIPLE RANDOM DONOR PLATELET TRANSFUSIONS [J].
BRAND, A ;
CLAAS, FHJ ;
VOOGT, PJ ;
WASSER, MNJM ;
EERNISSE, JG .
VOX SANGUINIS, 1988, 54 (03) :160-166
[9]
COHEN JJ, 1993, IMMUNOL TODAY, V14, P126, DOI 10.1016/0167-5699(93)90214-6
[10]
Process control of filtered red blood cells: which counting method? [J].
Conte, R ;
Bontadini, A ;
Cirillo, D ;
Fruet, F .
TRANSFUSION MEDICINE, 1997, 7 (03) :217-219