Optimization of the reaction conditions for the peroxyoxalate chemiluminescence detection system of fluorescent compounds in a high-performance liquid chromatography

被引:9
作者
Gohda, R [1 ]
Kimoto, K [1 ]
Santa, T [1 ]
Fukushima, T [1 ]
Homma, H [1 ]
Imai, K [1 ]
机构
[1] UNIV TOKYO,FAC PHARMACEUT SCI,TOKYO 113,JAPAN
关键词
peroxyoxalate chemiluminescence; batch method; high-performance liquid chromatography; bis[4-nitro-2-(3,6,9-trioxadecyloxycarbonyl)phenyl]oxalate; dipyridamole; dansylated valine;
D O I
10.2116/analsci.12.713
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Using an instrument of automatic fluid injection (batch method), we optimized such reaction conditions as pH, concentration and kinds of buffer for the peroxyoxalate chemiluminscence (PO-CL) detection of fluorescent compounds for high-performance liquid chromatography (HPLC). The results were compared with those obtained by HPLC. Consequently, the usefulness of the batch method for investigating the reaction conditions for PO-CL detection in HPLC was demonstrated. With the optimized condition using a phosphate buffer for the eluent in HPLC, the detection limits for Dns-Val and dipyridamole were 70 amol and 20 amol on column (S/N=2), respectively.
引用
收藏
页码:713 / 719
页数:7
相关论文
共 21 条
[1]   CHEMI-LUMINESCENCE FROM REACTIONS OF BIS(PENTACHLOROPHENYL)OXALATE, HYDROGEN-PEROXIDE AND FLUORESCENT COMPOUNDS - KINETICS AND MECHANISM [J].
CATHERALL, CLR ;
PALMER, TF ;
CUNDALL, RB .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS II, 1984, 80 :823-836
[2]   ZERO-DEAD-VOLUME PEROXYOXALATE CHEMILUMINESCENCE DETECTION IN LIQUID-CHROMATOGRAPHY [J].
CEPAS, J ;
SILVA, M ;
PEREZBENDITO, D .
ANALYTICAL CHEMISTRY, 1995, 67 (23) :4376-4379
[3]   OXALATE HYDROGEN-PEROXIDE CHEMILUMINESCENCE REACTION - A F-19 NMR PROBE OF THE REACTION-MECHANISM [J].
CHOKSHI, HP ;
BARBUSH, M ;
CARLSON, RG ;
GIVENS, RS ;
KUWANA, T ;
SCHOWEN, RL .
BIOMEDICAL CHROMATOGRAPHY, 1990, 4 (03) :96-99
[4]   OPTIMIZATION OF A PEROXYOXALATE CHEMI-LUMINESCENCE DETECTION SYSTEM FOR THE LIQUID-CHROMATOGRAPHIC DETERMINATION OF FLUORESCENT COMPOUNDS [J].
DEJONG, GJ ;
LAMMERS, N ;
SPRUIT, FJ ;
BRINKMAN, UAT ;
FREI, RW .
CHROMATOGRAPHIA, 1984, 18 (03) :129-133
[5]  
DEJONG GJ, 1983, J CHROMATOGR, V492, P319
[6]  
DUBOIS JE, 1980, ACAD SCI SER C, V290, P369
[7]   STOPPED-FLOW DETERMINATION OF THE PARAMETERS AFFECTING THE APPLICATION OF PEROXYOXALATE CHEMI-LUMINESCENCE TO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETECTION [J].
HANAOKA, N ;
GIVENS, RS ;
SCHOWEN, RL ;
KUWANA, T .
ANALYTICAL CHEMISTRY, 1988, 60 (20) :2193-2197
[8]   POSTCOLUMN ADJUSTMENT OF CONDITIONS FOR PEROXYOXALATE CHEMILUMINESCENCE DETECTION FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
HANAOKA, N .
JOURNAL OF CHROMATOGRAPHY, 1990, 503 (01) :155-165
[9]   DETERMINATION OF FEMTOMOLE CONCENTRATIONS OF CATECHOLAMINES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH PEROXYOXALATE CHEMILUMINESCENCE DETECTION [J].
HIGASHIDATE, S ;
IMAI, K .
ANALYST, 1992, 117 (12) :1863-1868
[10]   BIS(2,4-DINITROPHENYL) OXALATE AS A CHEMI-LUMINESCENCE REAGENT IN DETERMINATION OF FLUORESCENT COMPOUNDS BY FLOW-INJECTION ANALYSIS [J].
HONDA, K ;
SEKINO, J ;
IMAI, K .
ANALYTICAL CHEMISTRY, 1983, 55 (06) :940-943