Multiresidue analysis of pesticides in agricultural products by GC-ECD after GPC and graphitized carbon column cleanup

被引:15
作者
Ueno, E
Oshima, H
Saito, I
Matsumoto, H
Nakazawa, H
机构
[1] Aichi Prefectural Inst Publ Hlth, Kita Ku, Nagoya, Aichi 4628576, Japan
[2] Hoshi Univ, Shinagawa Ku, Tokyo 1428501, Japan
来源
JOURNAL OF THE FOOD HYGIENIC SOCIETY OF JAPAN | 2004年 / 45卷 / 04期
关键词
pesticide residue; agricultural product; gel permeation chromatography (GPC); graphitized carbon column; Florisil mini-column; dual-column; (ECD) GC-ECD;
D O I
10.3358/shokueishi.45.212
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
A multiresidue method that enables determination of many pesticides in agricultural products by GC-ECD was studied. First, 63 pesticides were selected as agrochemicals commonly used in crop protection in this country, and/or found in agricultural products over the past 6 years (April 1996-March 2002) in Aichi Prefecture. A sample was extracted with acetonitrile and the acetonitrile layer was separated by salting-out. The extract was purified on a GPC system with a graphitized carbon columns, and then by a Florisil mini-column fractionation. The test solution was subjected to one-injection, dual-column GC with dual ECD (column: Stx-CLPesticides and Stx-CLPesticides2). The detection limits of the pesticides were in a suitable range (0.0001-0.01mug/ g) for monitoring pesticide residues in agricultural products. The method was applied to 203 commercial agricultural products to demonstrate its suitability for routine analysis.
引用
收藏
页码:212 / 217
页数:6
相关论文
共 8 条
[1]   EXPLANATION OF THE MATRIX-INDUCED CHROMATOGRAPHIC RESPONSE ENHANCEMENT OF ORGANOPHOSPHORUS PESTICIDES DURING OPEN-TUBULAR COLUMN GAS-CHROMATOGRAPHY WITH SPLITLESS OR HOT ON-COLUMN INJECTION AND FLAME PHOTOMETRIC DETECTION [J].
ERNEY, DR ;
GILLESPIE, AM ;
GILVYDIS, DM ;
POOLE, CF .
JOURNAL OF CHROMATOGRAPHY, 1993, 638 (01) :57-63
[2]   Simultaneous determination of pesticide residues in fruits and vegetables by GC/MS (SCAN mode) and HPLC [J].
Kakimoto, Y ;
Ohtani, Y ;
Funaki, N ;
Joh, T .
JOURNAL OF THE FOOD HYGIENIC SOCIETY OF JAPAN, 2003, 44 (05) :253-262
[3]  
KOBAYASHI H, 1991, J PESTIC SCI, V16, P405
[4]  
Ueno E, 2003, J AOAC INT, V86, P1241
[5]  
Ueno E, 2004, J AOAC INT, V87, P1003
[6]   Multiresidue analysis of pesticides in foods using acetonitrile extraction, gel permeation chromatography and mini-column cleanup, and dual-column GC-ECD [J].
Ueno, E ;
Oshima, H ;
Saito, I ;
Matsumoto, H .
JOURNAL OF THE FOOD HYGIENIC SOCIETY OF JAPAN, 2000, 41 (03) :178-187
[7]   Multiresidue analysis of nitrogen-containing and sulfur-containing pesticides in agricultural products using dual-column GC-NPD/FPD [J].
Ueno, E ;
Oshima, H ;
Saito, I ;
Matsumoto, H .
JOURNAL OF THE FOOD HYGIENIC SOCIETY OF JAPAN, 2002, 43 (02) :80-89
[8]   Multiresidue analysis of organophosphorus pesticides in vegetables and fruits using dual-column GC-FPD, -NPD [J].
Ueno, E ;
Oshima, H ;
Saito, I ;
Matsumoto, H .
JOURNAL OF THE FOOD HYGIENIC SOCIETY OF JAPAN, 2001, 42 (06) :385-393