Assessing glucose meter accuracy

被引:34
作者
Arabadjief, Darius [1 ]
Nichols, James H. [1 ]
机构
[1] Baystate Hlth Syst, Springfield, MA 01199 USA
关键词
accuracy; diabetes; glucose meters; self-monitoring of blood glucose;
D O I
10.1185/030079906X148274
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Background: Self-monitoring of blood glucose plays an important role in the management of diabetes, particularly in patients treated with insulin. Blood glucose meters must have sufficient accuracy to allow patients and clinicians to monitor glycemic control and then modify treatment accordingly. Although several standards have been proposed, a consensus about how to measure glucose meter accuracy is not available. Scope: An informal review of recently published articles dealing with glucose meter accuracy was conducted to provide recommendations for evaluating accuracy relevant to the practicing clinician. Findings: Whether in clinical practice or in accuracy studies, the accuracy of blood glucose meters is typically determined by comparing meter results to those obtained by a clinical laboratory method on samples collected from the same patient at the same time. However, multiple sample-related, analysis-related, and data display-related factors can have an impact on accuracy determination. Clinicians need to recognize these factors and take steps to minimize their impact when assessing the accuracy of glucose meters used by their patients. Conclusions: Although modern glucose meters show variable results with respect to analytical measures of accuracy, error grid analysis demonstrates that measurements deemed clinically acceptable approach 100%.
引用
收藏
页码:2167 / 2174
页数:8
相关论文
共 27 条
[1]
*AM ASS CLIN CHEM, GLUC STAND 2 PROT PR
[2]
*AM DIAB ASS, 2004, DIABETES CARE S1, V27, pS15
[3]
[Anonymous], 1996, DIABETES CARE, V19, pS62
[4]
Identifying variables associated with inaccurate self-monitoring of blood glucose: Proposed guidelines to improve accuracy [J].
Bergenstal, R ;
Pearson, J ;
Cembrowski, GS ;
Bina, D ;
Davidson, J ;
List, S .
DIABETES EDUCATOR, 2000, 26 (06) :981-989
[5]
Chen Ellen T, 2003, Diabetes Technol Ther, V5, P749, DOI 10.1089/152091503322526969
[6]
CHMIELEWSKI SA, 1995, AM J CLIN PATHOL, V104, pS59
[7]
EVALUATING CLINICAL ACCURACY OF SYSTEMS FOR SELF-MONITORING OF BLOOD-GLUCOSE [J].
CLARKE, WL ;
COX, D ;
GONDERFREDERICK, LA ;
CARTER, W ;
POHL, SL .
DIABETES CARE, 1987, 10 (05) :622-628
[8]
A comparison of blood glucose meters in Australia [J].
Cohen, M ;
Boyle, E ;
Delaney, C ;
Shaw, J .
DIABETES RESEARCH AND CLINICAL PRACTICE, 2006, 71 (02) :113-118
[9]
Accuracy of the EasyTouch blood glucose self-monitoring system: a study of 516 cases [J].
Dai, KS ;
Tai, DY ;
Ho, P ;
Chen, CC ;
Peng, WC ;
Chen, ST ;
Hsu, CC ;
Liu, YP ;
Hsieh, HC ;
Yang, CC ;
Tsai, MC ;
Mao, SJT .
CLINICA CHIMICA ACTA, 2004, 349 (1-2) :135-141
[10]
Diabetic Research in Children Network (Direcnet) Study Group, 2003, DIABETES TECHNOL THE, V5, P933