Surface-activated chemical ionization and high-flow gradient chromatography to reduce matrix effect

被引:12
作者
Cristoni, Simone
Bernardi, Luigi Rossi
Gerthoux, Piermario
Mocarelli, Paolo
Brambilla, Maura
Gonella, Elisabetta
Guidugli, Federico
Cantu, Marco
机构
[1] Univ Milan, CISI, Ctr Biomol Interdisciplinary Studies & Ind Applic, I-20090 Milan, Italy
[2] Ion Source & Biotechnol, Milan, Italy
[3] Monzino Cardiol Ctr, Milan, Italy
[4] Univ Milan, Dept Lab Med, Milan, Italy
[5] Thermoelectron SpA, Milan, Italy
[6] Univ Bologna, CIRB, Biotechnol Res Ctr, I-40126 Bologna, Italy
[7] Biotrack, Parco Tecnol Padano, Lodi, Italy
关键词
D O I
10.1002/rcm.2599
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The new atmospheric pressure chemical ionization source, named surface-activated chemical ionization (SACI), has been used in conjunction with high-flow gradient chromatography to reduce the matrix effect. This high-flow gradient chromatography approach avoids the co-elution of analyte and biological matrix compounds that leads to a reduction in quantitation errors due to matrix effect. However, this approach cannot be employed with the classical electrospray ionization (ESD source that usually works at low eluent flow (< 300 mu L/min). SACI can work at high eluent flow (100-2000 mu L/min) and can be employed in conjunction with high-flow gradient chromatography. The reduction in matrix effect in tacrolimus analysis in protein-precipitated blood samples, an important immunosuppressive agent for renal transplantation, is presented and discussed. Copyright (c) 2006 John Wiley & Sons, Ltd.
引用
收藏
页码:2376 / 2382
页数:7
相关论文
共 28 条
[1]  
Armstrong VW, 1998, CLIN CHEM, V44, P2516
[2]   Tacrolimus monitoring in renal transplantation: A comparison between high-performance liquid chromatography and immunoassay [J].
Borrows, R ;
Chusney, G ;
Loucaidou, M ;
Singh, S ;
James, A ;
Stichbury, J ;
Van Tromp, J ;
Cairns, T ;
Griffith, M ;
Hakim, N ;
McLean, A ;
Palmer, A ;
Papalois, V ;
Taube, D .
TRANSPLANTATION PROCEEDINGS, 2005, 37 (04) :1733-1735
[3]  
Braun F, 1996, TRANSPLANT P, V28, P3175
[4]   ATMOSPHERIC-PRESSURE IONIZATION MASS-SPECTROMETRY - CORONA DISCHARGE ION-SOURCE FOR USE IN LIQUID CHROMATOGRAPH MASS SPECTROMETER-COMPUTER ANALYTICAL SYSTEM [J].
CARROLL, DI ;
DZIDIC, I ;
STILLWELL, RN ;
HAEGELE, KD ;
HORNING, EC .
ANALYTICAL CHEMISTRY, 1975, 47 (14) :2369-2373
[5]   Rapid simultaneous quantification of immunosuppressants in transplant patients by turbulent flow chromatography combined with tandem mass spectrometry [J].
Ceglarek, U ;
Lembcke, J ;
Fiedler, GM ;
Werner, M ;
Witzigmann, H ;
Hauss, JP ;
Thiery, J .
CLINICA CHIMICA ACTA, 2004, 346 (02) :181-190
[6]   Surface-activated chemical ionization ion trap mass spectrometry in the analysis of drugs in dilute urine samples. Part II: analysis of morphine and other street drugs [J].
Cristoni, S ;
Cantu, M ;
Bernardi, LR ;
Gerthoux, P ;
Mocarelli, P ;
Brambilla, M ;
Gonella, E ;
Guidugli, F .
JOURNAL OF MASS SPECTROMETRY, 2005, 40 (12) :1609-1617
[7]   The role of different phenomena in the surface-activated chemical ionization (SACI) performance [J].
Cristoni, S ;
Bernardi, LR ;
Guidugli, F ;
Tubaro, N ;
Traldi, P .
JOURNAL OF MASS SPECTROMETRY, 2005, 40 (12) :1550-1557
[8]   Surface-activated chemical ionization in the analysis of arginine in plasma samples [J].
Cristoni, S ;
Cantù, M ;
Bernardi, LR ;
Gerthoux, P ;
Gonella, E ;
Brambilla, M ;
Cavalca, V ;
Zingaro, L ;
Guidugli, F .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (10) :1231-1236
[9]   Surface-activated chemical ionization ion trap mass spectrometry in the analysis of 21-deoxycortisol in blood [J].
Cristoni, S ;
Sciannamblo, M ;
Bernardi, LR ;
Biunno, I ;
Gerthoux, P ;
Russo, G ;
Chiumello, G ;
Mora, S .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (12) :1392-1396
[10]   Surface-activated no-discharge atmospheric pressure chemical ionization [J].
Cristoni, S ;
Bernardi, LR ;
Biunno, I ;
Tubar, M ;
Guidugli, F .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (17) :1973-1981