Array of potentiometric sensors for the analysis of creatinine in urine samples

被引:66
作者
Magalhaes, JMCS [1 ]
Machado, AASC [1 ]
机构
[1] Fac Ciencias Porto, Dept Chem, LAQUIPAI, P-4169007 Oporto, Portugal
关键词
D O I
10.1039/b201173e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of potentiometric biosensors for creatinine based on creatinine iminohydrolase (E. C. 3.5.4.21) immobilized on chitosan membranes coupled to a nonactin based ammonium ion selective electrode is described. The response characteristics of three types of biosensors with the enzyme immobilized by three different procedures were evaluated. The biosensors with better response characteristics were obtained by coupling the ammonium ion selective electrodes to chitosan membranes with the enzyme immobilized by adsorption. The linear response range of these biosensors to creatinine was 10(-4) to 10(-2) M, the response time was between 30 and 60 s, they showed an operational lifetime of 44 days and the slope of the response to creatinine in the first day varied between 50 and 52 mV decade(-1). An array of six potentiometric sensors, constituted by two creatinine biosensors and four ion selective electrodes for potassium, sodium, ammonium and calcium was calibrated and a multivariate model based on PLS1 for the response to creatinine was obtained and validated. The array was used for the analysis of creatinine in urine samples and the results were compared with the results of a clinical analysis laboratory, based on the Jaffe reaction.
引用
收藏
页码:1069 / 1075
页数:7
相关论文
共 71 条
[1]   BIOSENSORS BASED ON CONDUCTING FILLED POLYMER ALL-SOLID-STATE PVC MATRIX MEMBRANE ELECTRODES [J].
ALEGRET, S ;
MARTINEZFABREGAS, E .
BIOSENSORS, 1989, 4 (05) :287-297
[2]   MULTICOMMUTATION IN FLOW-ANALYSIS .3. SPECTROPHOTOMETRIC KINETIC DETERMINATION OF CREATININE IN URINE EXPLOITING A NOVEL ZONE SAMPLING APPROACH [J].
ARAUJO, AN ;
LIMA, JLFC ;
REIS, BF ;
ZAGATTO, EAG .
ANALYTICA CHIMICA ACTA, 1995, 310 (03) :447-452
[3]   CHARACTERIZATION OF BIOSENSORS BASED ON MEMBRANES CONTAINING A CONDUCTING POLYMER [J].
BATTILOTTI, M ;
COLAPICCHIONI, C ;
GIANNINI, I ;
PORCELLI, F ;
CAMPANELLA, L ;
CORDATORE, M ;
MAZZEI, F ;
TOMASSETTI, M .
ANALYTICA CHIMICA ACTA, 1989, 221 (01) :157-161
[4]   SPARINGLY SELECTIVE ION-SELECTIVE ELECTRODE ARRAYS FOR MULTICOMPONENT ANALYSIS [J].
BEEBE, K ;
UERZ, D ;
SANDIFER, J ;
KOWALSKI, B .
ANALYTICAL CHEMISTRY, 1988, 60 (01) :66-71
[5]   NONLINEAR CALIBRATION USING PROJECTION PURSUIT REGRESSION - APPLICATION TO AN ARRAY OF ION-SELECTIVE ELECTRODES [J].
BEEBE, KR ;
KOWALSKI, BR .
ANALYTICAL CHEMISTRY, 1988, 60 (20) :2273-2278
[6]  
BEEBE KR, 1998, CHEMOMETRICS PRACTIC, P250
[7]   PROCESSING OF SIGNALS FROM AN ION-SELECTIVE ELECTRODE ARRAY BY A NEURAL NETWORK [J].
BOS, M ;
BOS, A ;
VANDERLINDEN, WE .
ANALYTICA CHIMICA ACTA, 1990, 233 (01) :31-39
[8]   Introduction to multivariate calibration in analytical chemistry [J].
Brereton, RG .
ANALYST, 2000, 125 (11) :2125-2154
[9]  
CABEZA AS, 1991, ANAL LETT, V24, P1741
[10]   SUITABLE POTENTIOMETRIC ENZYME SENSORS FOR UREA AND CREATININE [J].
CAMPANELLA, L ;
SAMMARTINO, MP ;
TOMASSETTI, M .
ANALYST, 1990, 115 (06) :827-830