Biomaterial-associated persistence of Streptococcus epidermidis in pericatheter macrophages

被引:101
作者
Boelens, JJ
Dankert, J
Murk, JL
Weening, JJ
van der Poll, T
Dingemans, KP
Koole, L
Laman, JD
Zaat, SAJ
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Med Microbiol, NL-1105 AZ Amsterdam, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Pathol, NL-1105 AZ Amsterdam, Netherlands
[3] Univ Amsterdam, Acad Med Ctr, Dept Expt Internal Med, NL-1105 AZ Amsterdam, Netherlands
[4] Maastricht Ctr Biomat Res, Maastricht, Netherlands
[5] Erasmus Univ, Dept Immunol, NL-3000 DR Rotterdam, Netherlands
关键词
D O I
10.1086/315369
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 [免疫学];
摘要
Biomaterial surfaces may be modified to reduce bacterial adhesion. The susceptibility in mice to Staphylococcus epidermidis infection in tissue surrounding the commonly used catheter materials-silicon elastomer (SE), polyamide (PA), and their surface-modified polyvinylpyrrolidone (PVP)-grafted derivatives, SE-PVP and PA-PVP, respectively-was assessed. Abscesses developed around SE-PVP Around SE, PA, and PA-PVP catheters, no signs of infection were observed, although mice carrying PA-PVP developed septicemia after 14-21 days. S. epidermidis was cultured from the tissue surrounding PA-PVP segments. Cells around PA-PVP segments containing large numbers of bacteria were identified as macrophages by use of immunohistochemistry and electron microscopy. This persistence of intracellular bacteria was also observed around SE-PVP, SE, and PA, catheters, although to a lesser extent. The cytokine profiles around the 4 materials were different. Implanted biomaterial induces an inflammatory response favorable to the persistence of S. epidermidis. Intracellular persistence of bacteria inside macrophages may be a pivotal process in the pathogenesis of biomaterial-associated infection.
引用
收藏
页码:1337 / 1349
页数:13
相关论文
共 56 条
[1]
Inflammatory response to implants [J].
Anderson, J.M. .
ASAIO Transactions, 1988, 34 (02) :101-107
[2]
Andrade J.D., 1985, SURFACE INTERFACIAL, V1, P249, DOI [10.1007/978-1-4684-8610-0_7, DOI 10.1007/978-1-4684-8610-0_7]
[3]
PRODUCTION OF EXPERIMENTAL ENDOCARDITIS BY COAGULASE-NEGATIVE STAPHYLOCOCCI - VARIABILITY IN SPECIES VIRULENCE [J].
BADDOUR, LM ;
CHRISTENSEN, GD ;
HESTER, MG ;
BISNO, AL .
JOURNAL OF INFECTIOUS DISEASES, 1984, 150 (05) :721-727
[4]
Bisno AL, 1994, INFECT ASS INDWELLIN
[5]
Cellular responses to interferon-gamma [J].
Boehm, U ;
Klamp, T ;
Groot, M ;
Howard, JC .
ANNUAL REVIEW OF IMMUNOLOGY, 1997, 15 :749-795
[6]
BOELENS J, 1998, 38 INT C ANT AG CHEM
[7]
MACROPHAGE DEACTIVATION BY INTERLEUKIN-10 [J].
BOGDAN, C ;
VODOVOTZ, Y ;
NATHAN, C .
JOURNAL OF EXPERIMENTAL MEDICINE, 1991, 174 (06) :1549-1555
[8]
EXPERIMENTAL FOREIGN-BODY INFECTIONS IN MICE CHALLENGED WITH SLIME-PRODUCING STAPHYLOCOCCUS-EPIDERMIDIS [J].
CHRISTENSEN, GD ;
SIMPSON, WA ;
BISNO, AL ;
BEACHEY, EH .
INFECTION AND IMMUNITY, 1983, 40 (01) :407-410
[9]
ADHERENCE OF SLIME-PRODUCING STRAINS OF STAPHYLOCOCCUS-EPIDERMIDIS TO SMOOTH SURFACES [J].
CHRISTENSEN, GD ;
SIMPSON, WA ;
BISNO, AL ;
BEACHEY, EH .
INFECTION AND IMMUNITY, 1982, 37 (01) :318-326
[10]
ADHERENCE OF COAGULASE-NEGATIVE STAPHYLOCOCCI TO PLASTIC TISSUE-CULTURE PLATES - A QUANTITATIVE MODEL FOR THE ADHERENCE OF STAPHYLOCOCCI TO MEDICAL DEVICES [J].
CHRISTENSEN, GD ;
SIMPSON, WA ;
YOUNGER, JJ ;
BADDOUR, LM ;
BARRETT, FF ;
MELTON, DM ;
BEACHEY, EH .
JOURNAL OF CLINICAL MICROBIOLOGY, 1985, 22 (06) :996-1006