Detection of volatile organic compounds (VOCs) in aqueous solution at low parts-per-trillion (ppt) levels is accomplished using a very simple and efficient on-line preconcentration cryotrap membrane introduction mass spectrometry (CT-MIMS) system, The conventional MIMS probe is modified so that the membrane interface is placed about 15 cm away from the ion source, A U-shaped trap tube is then inserted between the membrane interface and the ion source, Cryotrapping is performed with liquid nitrogen for 15 min, followed by fast heating at similar to 15 degrees C s(-1), which thermally releases the condensed VOCs almost at once into the ion source region of a quadrupole mass spectrometer. By applying electron ionization and a selective ion monitoring scan mode, a very sharp and intense peak is obtained. The performance of the CT-MIMS system was compared with that of conventional MIMS, and after reaching the best conditions for the trapping and heating cycles, an improvement factor in signal intensity of about 100 was observed for a series of VOCs. The extraordinary sensitivity of CT-MIMS system allows VOCs to be detected at very low concentrations, detection limits being typically on the order of 10-20 ppt. The results also show excellent linearity and reproducibility fur the system.
引用
收藏
页码:3502 / 3506
页数:5
相关论文
共 21 条
[2]   DETERMINATION OF VOLATILE ORGANIC-COMPOUNDS AT THE PARTS-PER-TRILLION LEVEL IN COMPLEX AQUEOUS MATRICES USING MEMBRANE INTRODUCTION MASS-SPECTROMETRY [J].
BAUER, S ;
SOLYOM, D .
ANALYTICAL CHEMISTRY, 1994, 66 (24) :4422-4431
[3]   DIRECT INSERTION MEMBRANE PROBE FOR SELECTIVE INTRODUCTION OF ORGANIC-COMPOUNDS INTO A MASS-SPECTROMETER [J].
BIER, ME ;
KOTIAHO, T ;
COOKS, RG .
ANALYTICA CHIMICA ACTA, 1990, 231 (02) :175-190
[4]  
EBERLIN MN, 1996, 44 ASMS C MASS SPECT
[5]   The generation, stability, dissociation and ion molecule chemistry of sulfinyl cations in the gas phase [J].
Gozzo, FC ;
Sorrilha, AEPM ;
Eberlin, MN .
JOURNAL OF THE CHEMICAL SOCIETY-PERKIN TRANSACTIONS 2, 1996, (04) :587-596
[6]   THE IONIZED METHYLENE TRANSFER FROM THE DISTONIC RADICAL-CATION (CH2)-C-+-O-CH2-CENTER-DOT TO HETEROCYCLIC-COMPOUNDS - A PENTAQUADRUPOLE MASS-SPECTROMETRIC STUDY [J].
GOZZO, FC ;
EBERLIN, MN .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1995, 6 (07) :554-563
[7]   Fast multidimensional (3D and 4D) MS(2) and MS(3) scans in a high-transmission pentaquadrupole mass spectrometer [J].
Juliano, VF ;
Gozzo, FC ;
Eberlin, MN ;
Kascheres, C ;
doLago, CL .
ANALYTICAL CHEMISTRY, 1996, 68 (08) :1328-1334
[8]   MEMBRANE INTRODUCTION MASS-SPECTROMETRY [J].
KOTIAHO, T ;
LAURITSEN, FR ;
CHOUDHURY, TK ;
COOKS, RG ;
TSAO, GT .
ANALYTICAL CHEMISTRY, 1991, 63 (18) :A875-+
[9]   MEMBRANE MASS-SPECTROMETRY FOR THE DIRECT TRACE ANALYSIS OF VOLATILE ORGANIC-COMPOUNDS IN AIR AND WATER [J].
LAPACK, MA ;
TOU, JC ;
ENKE, CG .
ANALYTICAL CHEMISTRY, 1990, 62 (13) :1265-1271
[10]   ONLINE MONITORING OF BIOLOGICAL REACTIONS AT LOW PARTS-PER-TRILLION LEVELS BY MEMBRANE INLET MASS-SPECTROMETRY [J].
LAURITSEN, FR ;
GYLLING, S .
ANALYTICAL CHEMISTRY, 1995, 67 (08) :1418-1420