Statistical design-principal component analysis optimization of a multiple response procedure using cloud point extraction and simultaneous determination of metals by ICPOES

被引:81
作者
Bezerra, Marcos A.
Bruns, Roy E.
Ferreira, Sergio L. C.
机构
[1] Univ Fed Bahia, Inst Quim, Grp Pesquisa Quim Anal, BR-40170290 Salvador, BA, Brazil
[2] Univ Estadual Sudoeste Bahia, Dept Quim & Exatas, Lab Quim Anal, BR-45200190 Salvador, Brazil
[3] Univ Estadual Campinas, Inst Quim, BR-13083970 Campinas, SP, Brazil
关键词
cloud point extraction; Doehlert design; simultaneous determination in inductively coupled plasma optical emission spectrometry (ICP OES); principal component analysis; response surface analysis; ATOMIC-ABSORPTION-SPECTROMETRY; WATER SAMPLES; PARENTERAL SOLUTIONS; TRACE AMOUNTS; PRECONCENTRATION; CADMIUM; COPPER; LEAD;
D O I
10.1016/j.aca.2006.07.056
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A procedure has been developed for the simultaneous determination of traces amounts of Cd, Cr, Cu, Mn, Ni and Pb from saline oil-refinery effluents and digested vegetable samples using inductively coupled plasma optical emission spectrometry (ICP OES). The procedure is based on cloud point extraction (CPE) of these metals as 2-(bromo-2-pyridylazo)-5-diethyl-amino-phenol (Br-PADAP) complexes into a micellar phase of octylphenoxypolyethoxyethanol (Triton X-114). Optimization of the procedure was performed by response surface methodology (RSM) using a Doehlert design. Principal components (PC) were used to simplify the multiple response analysis. A response surface for the first PC score is useful in determining the optimum conditions for the Cd, Cr, Cu, Mn and Pb determinations whereas the second PC is highly correlated with the Ni response. Improvement factors of 22, 36, 46, 25, 65 and 39, along with limits of detection (3 sigma(B)) of 0.081, 0.79, 0.38, 0.83, 0.28 and 0.69 mu L-1, and precision expressed as relative standard deviation (%R.S.D., n = 8, 20.0 mu g L-1) of 1.5, 2.2, 3.5, 2.6, 2.5 and 2.5 were achieved for Cd, Cr, Cu, Mn, Ni and Pb, respectively. The accuracy was evaluated by spike tests in oil-refinery effluent samples and analysis of a vegetable certified reference material (NIST 1571, orchard leaves). Results found were in agreement with certified values. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:251 / 257
页数:7
相关论文
共 30 条
[1]  
[Anonymous], STAT WIND
[2]  
[Anonymous], 1984, CHEMOMETRICS MATH ST
[3]  
[Anonymous], 2006, Statistical Design-Chemometrics
[4]   A pre-concentration procedure using cloud point extraction for the determination of manganese in saline effluents of a petroleum refinery by flame atomic absorption spectrometry [J].
Bezerra, MD ;
Conceiçao, ALB ;
Ferreira, SLC .
MICROCHIMICA ACTA, 2006, 154 (1-2) :149-152
[5]   Cloud point extraction as a procedure of separation and pre-concentration for metal determination using spectroanalytical techniques: A review [J].
Bezerra, MD ;
Arruda, MAZ ;
Ferreira, SLC .
APPLIED SPECTROSCOPY REVIEWS, 2005, 40 (04) :269-299
[6]   Cloud-point extraction for the determination of Cd, Pb and Pd in blood by electrothermal atomic absorption spectrometry, using Ir or Ru as permanent modifiers [J].
Borges, DLG ;
da Veiga, MAMS ;
Frescura, VLA ;
Welz, B ;
Curtius, AJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (05) :501-507
[7]   Simultaneous optimization of the solid-phase extraction of organochlorine and organophosphorus pesticides using the desirability function [J].
Carro, AM ;
Lorenzo, RA .
ANALYST, 2001, 126 (07) :1005-1010
[8]   Determination of cadmium, copper, lead and zinc in water samples by flame atomic absorption spectrometry after cloud point extraction [J].
Chen, JR ;
Teo, KC .
ANALYTICA CHIMICA ACTA, 2001, 450 (1-2) :215-222
[9]  
da Silva MAM, 2001, SPECTROCHIM ACTA B, V56, P1941
[10]  
da Silva MAM, 2000, SPECTROCHIM ACTA B, V55, P803